EasyManua.ls Logo

Drivecon Crane Commander Series - Page 13

Default Icon
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Table 2.4c Inverter Thermal Characteristics
Heat loss of
inverter
(Watts) at
full load*
H: Calori-
Metric value
of heat
radiated by
inverter.*
(K cal/hr.)
Q:
Necessary
ventilation
volume t
= 10°C
(ft³/min.)
S: Vent port
area
(Minimum
value (in²))
Minimum
surface area
in² steel
enclosure
without
venting 40°
Amb.
t=10°C
Minimum
surface area
in² plastic
enclosure
without
venting 40°
Amb.
t=10°C
Model kW
CC-204
CC-404
0.4 35 30.1 6.1 2.3 1,085 1,550
CC-207
CC-407
0.75 40 34.4 7.1 2.3 1,131 1,767
CC-215
CC-415
1.5 60 51.6 10.7 2.8 1,689 2,650
CC-222
CC-422
2.2 70 60.2 12.5 3.4 1,968 3,100
CC-237
CC-437
4.0 135 116.1 23.6 11.5 3,782 5,983
CC-255
CC-455
5.5 190 163.4 37.6 15.3 5,349 8,418
CC-275
CC-475
7.5 240 206.4 42.5 20.0 6,760 10,620
CC-2110
CC-4110
11 310 266.6 54.6 25.6 9,612 13,736
CC-2150
CC-4150
15 453 389.6 80.0 37.5 14,050 20,062
CC-2220
CC-4220
22 673 578.8 118.9 55.8 20,868 29,813
∆∆
* Approximate values.