INSTALLATION MANUAL
Ø
If applicable, do not plaster on or over the edges of the construction frame, because:
the heat of the appliance could cause cracks;
it will no longer be possible to remove/place the glass pane.
Ø
When using stone-like materials and/or a plaster finishing, allow the chimney breast to dry for at least six weeks
prior to using the appliance in order to prevent cracks.
5.6Placingthecontrolhatch (if applicable)
The control hatch (also see paragraphs 5.4 and 5.5) is placed as low as possible in the chimney breast.
!Caution
The bottom of the control hatch may not be placed higher in the appliance than the burner surface.
Place control hatch and bracket with gas control and accessories indoors in a dry place only!
A number of components are placed in the control hatch, such as data plate, gas control, receiver belonging to the
remote control and, if applicable, the components belonging to the DRU Powervent system
®
.
Place the control hatch as follows; see Appendix 3, fig. 3 for details:
Ø
Make an opening in the chimney breast, as described in the manual for the control hatch.
Ø
Place the inner frame (1); unscrew bolts (5) for this.
!Tip
When the chimney breast is made of bricks, the inner frame can be built with bricks at the same time
When using a different material, you can glue the inner frame or fix it with four flush screws.
Ø
Mount the gas control to the brackets of the inner frame (2).
Ø
Check whether pipes and connections are free from dirt;
Ø
Reconnect the pipes to the gas control.
!Caution
Avoid kinks in the pipes;
Tighten the flexible gas pipe and the pilot burner pipe until they are gastight.
First tighten the thermocouple by hand and;
Then tighten it a quarter turn using a suitable spanner;
The pilot burner pipe must be protected against possible corrosive influences as a result of, for example,
humidity, cement that has fallen down, dirt that has fallen down from the chimney, etc. The pilot burner pipe
should remain permanently free from the ground and the walls of the room in which the appliance is built in.
When installing in an existing fireplace, or if it is not possible to keep the pipes free, the pipe should be
protected against corrosion by means of a jacket.
Ø
Prevent dirt in gas pipes and connections.
Ø
Connect the gas pipe to the gas tap.
Ø
Bleed the gas pipe.
Ø
Place the receiver in the holder (3); for connecting, see section 6.1.
Ø
Place the data plate in its intended clamp (6).
Ø
Fix the outer frame with door (4) to the inner frame using 2 socket cap screws (5).
!Tip
You can place the outer frame in such a way, that the door turns to the left or to the right.
5.7Fluegasdischargesysteminapplianceswithopencombustion
For connection to an existing chimney without a discharge pipe or flexible SS discharge - only allowed in Great
Britain - the instructions provided in the separately supplied booklet 'Fitting into a conventional class 1 chimney'
apply. In addition to the installation instructions, this booklet also contains supplementary tests. In this situation
we recommend using a stainless steel flexible discharge pipe over the complete length, with a draught increasing
hood.
5.7.1General
The connection dimensions and the minimum length of the discharge system are indicated in Annex 2, table 2.
The appliance should be connected in accordance with the applicable national, local and constructional
(installation) regulations. You should only install the appliance in a well ventilated room which complies with the
applicable national, local and constructional (installation) regulations, in order to guarantee sufficient air supply.