EasyManua.ls Logo

DSC PC1500RK

DSC PC1500RK
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
TABLE OF CONTENTS
TABLE OF CONTENTS 1
FEATURES 2
Keypad Programmable......................................................... 2
EEPROM Memory ................................................................. 2
Static/Lightning Protection.................................................... 2
Supervision ........................................................................... 2
Operation .............................................................................. 2
SPECIFICATIONS 2
PC1550 Control Panel .......................................................... 2
PC1500RK Keypad ............................................................... 2
INSTALLATION 3
Mounting the Panel ............................................................... 3
Mounting the Keypad ........................................................... 3
Auxiliary Power Connection .................................................. 3
PGM Terminal Connections .................................................. 3
Bell/Siren Connection ........................................................... 3
Keypad Wiring ...................................................................... 3
Fire Zone Wiring ................................................................... 3
Burglary Zone Wiring ............................................................ 3
Battery Connection ............................................................... 3
Telephone Line Wiring .......................................................... 3
GUIDELINES FOR LOCATING SMOKE DETECTORS 4
KEYPAD FUNCTIONS 5
Introduction ........................................................................... 5
Master Code ......................................................................... 5
2nd Master Code .................................................................. 5
Installer’s Programming Code .............................................. 5
Arming .................................................................................. 5
Auto-Bypass/Home-Away Arming ........................................ 5
Arming Without Entry Delay .................................................. 5
Disarming.............................................................................. 5
Zone Bypassing .................................................................... 5
Trouble Conditions ............................................................... 5
Alarm Memory....................................................................... 6
Downloading Callup Command ........................................... 6
User Programming Commands ............................................ 6
EEPROM Reset ..................................................................... 6
User Function Commands .................................................... 6
Utility Output Command ....................................................... 7
Installer’s Programming Command ...................................... 7
Arming without Entry Delay .................................................. 7
Arming For The Night ........................................................... 7
Quick-Exit Command ............................................................ 7
Quick-Arm Command ........................................................... 7
Keypad Zones ...................................................................... 7
PROGRAMMING 8
How to Program .................................................................... 8
Program Data Review ........................................................... 8
Binary Data Display .............................................................. 8
HEX Data Programming........................................................ 8
Programming Sections ......................................................... 8
[00] Binary Programming .................................................... 8
[01] 1st Phone Number ....................................................... 8
[02] 1st Account Code ........................................................ 9
[03] 2nd Phone Number ...................................................... 9
[04] 2nd Account Code ....................................................... 9
[05] to [10] Reporting Codes ................................................ 9
[05] Zone Alarm Reporting Codes ...................................... 9
[06] Zone Restoral Reporting Codes .................................. 9
[07] Closing (Arming) Reporting Codes.............................. 9
Partial Closing Reporting Code ................................... 9
[08] Opening (Disarming) Reporting Codes .........................
After Alarm Reporting Code ......................................... 9
[09] Priority Alarms and Restorals ....................................... 9
[10] Maintenance Alarms and Restorals ........................... 10
[11] Zone Definitions ......................................................... 10
[12] 1st System Option Code ............................................ 11
[13] 2nd System Option Code ........................................... 11
[14] 3rd System Option Code............................................ 11
[15] Communication Variables .......................................... 11
[16] Zone Bypass Mask..................................................... 11
[17] System Times ............................................................. 11
[18] Auxiliary Delay Loop Entry/Exit Times ....................... 12
[19] System Clock Times ................................................... 12
[20] New Installer’s Code .................................................. 12
[21] New Master Code ...................................................... 12
[22] 2nd Master Code ....................................................... 12
[23] Communication Formats ............................................ 12
[24] Programmable Output Options .................................. 13
(PGM Terminal) .......................................................... 13
[25] Communicator Call Directions ................................... 13
[26] Downloading Telephone Number .............................. 13
[27] Downloading Access Code ....................................... 13
[28] Panel Identification Code ........................................... 13
[29] Number of Rings Before Answering .......................... 13
[30] Reset to Factory Default............................................. 13
[31] 4th System Option Code ............................................ 14
[32] 5th System Option Code ............................................ 14
[33] Answering Machine Double Call Timer...................... 14
[34] 6th System Option Code ............................................ 14
[35] LINKS1000 Test Reporting Code............................... 14
[36] Keypad Lockout Control ............................................ 14
[90] Installer’s Lockout Enable .......................................... 14
[91] Installer’s Lockout Disable ......................................... 14
FOR THE RECORD 15
PROGRAMMING WORK SHEETS 16

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the DSC PC1500RK and is the answer not in the manual?

DSC PC1500RK Specifications

General IconGeneral
PGMs2
LED IndicatorYes
Operating Temperature32°F to 120°F (0°C to 49°C)
Humidity Range93% RH, non-condensing
ComplianceUL

Summary

Features and Specifications

Keypad Programmable

Panel is programmable from keypad.

Supervision

Monitors battery, AC power, system clock, watchdog.

Control Panel Specifications

Details on the PC1550 control panel, including zones, outputs, and power.

Keypad Specifications

Details on the PC1500RK keypad, including keys, lights, and dimensions.

Installation Procedures

Panel Mounting

Instructions for panel installation location and mounting.

Keypad Mounting & Wiring

Guidelines for keypad placement, mounting, and wiring.

Zone Wiring

Specific wiring for fire and burglary zones.

Power & Communication Wiring

Connects auxiliary power, bell, battery, and telephone lines.

Smoke Detector Placement Guidelines

General Placement Guidelines

Recommendations for placing smoke detectors in living units.

Mounting Considerations

Details on avoiding "dead air space" for optimal detection.

Keypad Functions and Operation

Master Code and User Commands

Covers Master Code, 2nd Master, Installer's Code, and User Functions.

Arming and Disarming

Steps and conditions for arming, auto-bypass, and disarming the system.

Zone Bypassing

How to bypass zones and rules for cancellation.

Trouble Conditions

Indicates causes of "Trouble" light and how to silence it.

Keypad Functions (Continued)

Alarm Memory

How to view stored alarms and history levels.

Downloading Commands

Initiating calls and user programming.

System Resets and Functions

Covers EEPROM Reset and User Function Commands.

Keypad Functions (Continued)

Quick Arming and Exit Options

Covers arming without entry delay, quick-exit, and quick-arm.

Keypad Zone Functions

Describes the function of [F], [A], and [P] keys.

Programming Overview

How to Program

General steps to enter programming mode.

Program Data Review

How to review programmed data.

HEX Data Programming

How to enter HEX format data.

Programming Sections

General overview of programming sections.

Programming Sections

Phone and Account Codes

Covers programming for phone numbers and account codes.

Reporting Codes

Programming codes for alarms, restorals, openings, and priority events.

Programming Sections (Continued)

Maintenance Alarms and Restorals

Programming codes for maintenance events.

Zone Definitions

Defining zone types, response, and behavior.

Programming Sections (Continued)

System Option Codes

Configuring system options via zone lights.

Communication Variables

Setting communication retry and delay parameters.

Zone Bypass Mask

Controlling which zones can be bypassed.

System Times

Setting various time delays and cut-off times.

Programming Sections (Continued)

Auxiliary Delay Loop Times

Setting specific entry/exit delays for auxiliary loops.

System Clock and Auto-Arm Times

Setting automatic arming and test transmission times.

Installer and Master Codes

Changing installer and master user codes.

Communication Formats

Selecting communication formats for phone numbers.

Programmable Output Options

Configuring the PGM terminal for various functions.

Programming Sections (Continued)

Communicator Call Directions

Defining call order for reporting events.

Downloading Configuration

Setting telephone number, access code, and panel ID.

Reset to Factory Default

Performing a software reset to default settings.

Programming Sections (Continued)

System Option Codes

Configuring 4th, 5th, and 6th system option codes.

Keypad Lockout Control

Configuring keypad lockout and duration.

Installer Lockout Management

Enabling or disabling installer lockout.

Zone Definitions and Options

Zone Definition Details

Explains first and second digits for zone types.

System Option Code Configuration

Explains how to configure system options via zone lights.

Communication and Time Settings

Communication Variables and Bypass Mask

Covers communication retries, delays, and zone bypass control.

System Times and Codes

Covers system times, clock, installer, and master codes.

Communication Configuration

Communication Formats

Selecting communication formats for phone numbers.

Programmable Output Options

Configuring the PGM terminal for various functions.

Communicator Call Directions

Defining call order for reporting events.

Downloading Configuration

Setting telephone number, access code, and panel ID.

System Options and Lockout Control

System Option Codes

Configuring 4th, 5th, and 6th system option codes.

Keypad Lockout Control

Configuring keypad lockout and duration.

Installer Lockout Management

Enabling or disabling installer lockout.

Wiring Diagram and Safety Notices

Control Panel Wiring Diagram

Diagram showing panel connections.

Keypad Wiring

Details for wiring PC1500RK keypads.

Fire Zone Wiring Diagram

Diagram for connecting fire alarm zones.

Safety and Compliance Notices

Includes Industry Canada and user cautions.

Limited Warranty and Warnings

Warranty Information

Covers warranty goods, conditions, and repairs.

System Risks and Precautions

Covers potential system failures, installation, and device risks.