DSC PC1575 Program Sheet
Supported PC5580 Escort
DSC Modules PC5400 Printer Module
DLM-1/DLM-4 Downlook Module
Cannot use PC5132 Wireless Receiver or Sensors
Enter Program * 8 1575 (READY, ARMED and TROUBLE Lights should flash)
Exit Program #
Move to location Enter 2-digit location, some areas may require # to exit
Default Panel 1. Connect wire from Zone 1 to PGM1
2. Power up panel, wait 10 seconds
3. If Zone 1 turns ON panel is defaulted, if not panel is locked
Enable Download * + 6 + Master Code + 5 (Enables for 1 hour)
(System also enables downloading for 1 hour if powered down then up)
Hex Program A = * 1 *, B = * 2 *, C = * 3 *, D = * 4 *, E = * 5 *, F = * 6 *
[00] Keypad Assignment (must be done at each keypad)
[0] Slot (Valid entries are 11-18 for the Slot)
[1] Function Key 1 Assignment (Default = 03)
[2] Function Key 2 Assignment (Default = 04)
[3] Function Key 3 Assignment (Default = 06)
[4] Function Key 4 Assignment (Default = 14)
[5] Function Key 5 Assignment (Default = 16)
00 Null Key (Not Used) 07 * 6 4 System Test 13 * 7 1 Utility Output
01 Not used 08 * 1 Bypass Mode 14 * 7 2 Sensor Reset
02 Not used 09 * 2 Trouble Display 15 Not Used
03 Stay Arm 10 * 3 Alarm Memory 16 * 0 Quick Exit
04 Away Arm 11 * 5 User Programming 17 * 1 Reactivate Stay/Away's
05 * 9 No-Entry Arm 12 * 6 User Functions 18 Not Used
06 * 4 Chime On/Off
If multiple LCD keypads make 1 slot 8 to enable Zone description programming by downloader
[01] Zone 1-6 Definitions 00 Null (Not Used) 11 24 Hour Burglary
Default 01 Delay 1 12 24 Hour Heat
01 l_____l_____l Zone 1 02 Delay 2 13 Not Used
06 l_____l_____l Zone 2 03 Instant 14 24 Hour Hold-Up
03 l_____l_____l Zone 3 04 Interior 15 24 Hour Auxiliary
03 l_____l_____l Zone 4 05 Interior, Stay/Away 16 24 Hour Panic
03 l_____l_____l Zone 5 06 Delay, Stay/Away 17 24 Hour Emergency
03 l_____l_____l Zone 6 07 Delay 24 Hour Fire 18 24 Hour Sprinkler
08 Standard 24 Hour Fire 19 24 Hour Water
09 24 Hour Supervisory (Links) 20 24 Hour Freeze
10 24 Hour Supervisory Buzzer 21 24 Hour Latching Tamper
[02] System Times
Default
030 I _ _I _ _I _ _I Entry Delay 1 (000 to 255 seconds)
045 I _ _I _ _I _ _I Entry Delay 2 (000 to 255 seconds)
120 I _ _I _ _I _ _I Exit Delay (000 to 255 seconds)
004 I _ _I _ _I _ _I Bell Cut-off (000 to 255 minutes)
[03] Installer's Code
Default
1575 I _1 _I _5 _I _7 _I _5 _I
[04] Master Code
Default
1234 I _ _I _ _I _ _I _ _I
[05] Second Master Code
Default
AAAA I _ _
I _ _I _ _I _ _I
Created by Mark Leuck 02/02/2002 Monitronics International, Inc.