Self Contained Wireless Alarm System v1.0
18
[014] Second System Options
[015] Third System Options
[016] Fourth System Options
[023] Tenth System Options
Opt Def. ON OFF
1
Arm/Disarm Bell Squawk Enabled
Arm/Disarm Bell Squawk Disabled
2
Future Use
3
RF Jam Log After 5 Minutes
RF Jam Logs After 20 seconds
4
Aux Boost Enabled
Aux Boost Disabled
5
Future Use
6
Audible Exit With Urgency
Silent Exit Delay
7
Future Use
8
Fire Bell is Continuous
Fire Bell Follows Bell Cut-off
Opt Def. ON OFF
1
[F] Key Enabled
[F] Key Disabled
2
[P] Key Audible (Bell/Beeps)
[P] Key Silent
3
Quick Exit Enabled
Quick Exit Disabled
4
Quick Arming Enabled ([][0] and Function Keys)
Quick Arming Disabled (Function Key Requires Code)
5
Code Required for Bypassing
No Code Required
6
Master Code not Changeable
Master Code Changeable
7
TLM Enabled
TLM Disabled
8
System Tamper Enabled
System Tamper Disabled
Opt Def. ON OFF
1
Cross Zoning Enabled
Police Code enabled
2
Exit Delay Restart Enabled (required for CP-01)
Exit Delay Restart Disabled
3
Blank Keypad When Not Used
Keypad Always Active
4
Code Required to Remove Keypad Blanking
No Code Required
5
Keypad Backlighting Enabled
Keypad Backlighting Disabled
6
ID WKEY Not required for Disarming
ID WKEY Required for Disarming
7
Bypass Status Displayed While Armed
Bypass Status Not Displayed While Armed
8
Daylight Saving Time Enabled
Daylight Saving Time Disabled
Opt Def. ON OFF
1
[F] Key Beeps Only
[F] Key Beeps and Sounds Bell
2
Future Use
3
Test Transmission while Armed Only
Test Transmission while Armed/Disarmed
4
Test Transmission Counter in Hours
Test Transmission Counter in Days
5
Switching from Away to Stay Disabled
Away to Stay Toggle Option Permitted
*6
New Alarms will not disconnect 2-way Audio
New Alarms disconnect 2-way Audio
7
Trouble beeps are Silent
Trouble Beeps Sound Every 10 seconds
8
Keyswitch Arms in Away Mode
Keyswitch Arms in Stay or Away Mode
* Applies to SCW9047 version only. This option must be OFF for UL Listed Installations
WWW.DIYALARMFORUM.COM