Do you have a question about the DSE DSE6110 MKII and is the answer not in the manual?
Defines technical terms used in the manual for clarity and understanding.
Details the operational temperature range for the DSE modules and variants.
Outlines the voltage, current, and protection requirements for the module's power supply.
Describes the specifications for digital, analogue, and magnetic pickup inputs.
Details the types and specifications for USB, CAN, and DSENet® communication ports.
Provides physical dimensions, panel cutout, weight, and mounting details for the module.
Explains the function of each terminal on the module for wiring purposes.
Details wiring connections for DC supply, inputs, outputs, and sensors.
Illustrates typical wiring configurations for DSE6110 MKII and DSE6120 MKII modules.
Explains the function of each push-button on the module's front panel.
Lists engine parameters that can be monitored or derived from module inputs.
Describes how alarms are displayed, indicated, and managed on the module.
Details the sequence and operation when the module is in Manual Mode.
Explains how the generator operates automatically in Auto Mode.
Describes the module's ability to schedule automatic start/stop sequences.
Lists and describes warning alarms that indicate non-critical conditions.
Details electrical trip alarms that latch and stop the generator in a controlled manner.
Lists and describes shutdown alarms that immediately stop the generator.
Explains the Over Current Alarm, including IDMT curve functionality.
Describes how to access and use the main configuration editor on the front panel.
Lists adjustable parameters available for configuration via the front panel.
Lists common starting symptoms and their possible remedies.
Helps diagnose and resolve issues related to alarms displayed by the module.
Provides information on ordering additional connector plugs from the manufacturer.
Provides guidance on the proper disposal of electrical and electronic equipment.
| DC Supply | 8 V to 35 V continuous |
|---|---|
| Alternator Input Frequency | 50 Hz - 60 Hz at rated engine speed |
| Magnetic Input Frequency | 10, 000 Hz (max) |
| Storage Temperature Range | -40°C to +85°C |
| Maximum Humidity | 95% non-condensing |
| Input Voltage | 8 V to 35 V |
| Input Voltage Range | 8 V to 35 V |
| Cranking Dropouts | Able to survive 0 V for 50 ms providing supply was at least 10 V before dropout and supply recovers to 5 V |
| Communication Ports | RS485 |
| Dimensions (H x W x D) | 240 mm x 172 mm x 57 mm |
| Frequency Range | 3.5 Hz to 75 Hz |
| Relay Outputs | 4 |
| Protection Rating | IP65 (front) |
| Dimensions | 182 mm x 132 mm |