EasyManua.ls Logo

dunkermotoren BG 45x30 SI User Manual

Default Icon
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BG 45 SI
Motor Part No.
45x15 88545.070XX
45x30 88545.080XX
Instruction Manual
BLDC motor with parametrizable
motion controller integrated
Betriebsanleitung
Bürstenloser DC - Motor mit integriertem
parametrierbarem Drehzahlregler
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the dunkermotoren BG 45x30 SI and is the answer not in the manual?

dunkermotoren BG 45x30 SI Specifications

General IconGeneral
TypeBrushless DC Motor
Protection ClassIP40
Rated Speed3000 rpm
Rated Torque0.095 Nm
Stall Torque0.28 Nm
Stall Current4.5 A
Terminal Resistance5.3 Ω
Terminal Inductance1.8 mH
Torque Constant0.062 Nm/A
Speed Constant154 rpm/V
No-load speed4000 rpm
No-load current0.15 A
Nominal speed3000 rpm
Nominal torque0.095 Nm
Nominal current1.6 A

Summary

Instruction Manual

About this document

General Safety Warnings

Read and observe warnings to protect from danger and avoid device damage.

Safety instructions

General Safety Instructions

Essential safety instructions for operation, installation, and qualified personnel.

Technical data, accessories

Motor specification

Detailed electrical and performance specifications for BG 45x15 SI and BG 45x30 SI motor variants.

Protective functions

Over-temperature protection

Details on power stage shutdown if temperature exceeds 105°C and confirmation criteria.

Under voltage cut-off (logic supply)

Logic supply voltage monitoring for power stage shutdown below 8.5V, with confirmation at 9V.

Under voltage cut-off (power stage)

Power supply voltage monitoring for shutdown below 5V (1 sec), with confirmation at 6V.

Over voltage cut-off (logic supply)

Logic supply voltage monitoring for shutdown above 35V, with confirmation below 34V.

Over voltage cut-off (power stage supply)

Power stage supply voltage monitoring for shutdown above 33V/58V (1 sec), confirmation below 32V/57V.

Over current (I2t)

I2t protection function monitors and limits motor current to prevent damage.

Installation / terminal assignment

SI - Configurator

Using the SI-Configurator software to adapt and store motor parameters and functions.

Maintenance & Service

Maintenance, taking out of service and disposal

Information on the drive's maintenance-free design and procedures for taking it out of service and disposal.