Bedienungsanleitung
User's Manual
Manuel de l'utilisateur
Abluftüberwachungseinheit mit Ventilator und Aktivkohlelter
Exhaust Airow Unit with Fan and Activated Carbon Filter
Unité de contrôle du débit d'extraction d'air avec ventilateur et ltre à charbon
2.00.397 - 1 I
HNA-18 II Basic
Inliegende deutsche Fassung der Anleitung ist der Urtext, welchen inliegende Übersetzungen wiedergeben.
The German version of the manual enclosed herein is the original copy, reected in both translations herein.
La version allemande ci-après représente le texte original du manuel, rendu par les deux traductions ci-joint.

Table of Contents

Questions and Answers

  • K
    kwilsonAug 5, 2025
    What to do if exhaust airflow error shows on the LEDs in DÜPERTHAL Laboratory Equipment?
    • A
      Ashley GrahamAug 5, 2025
      If the exhaust airflow error appears on the LEDs, you should: * Clean the hose and/or clear the restriction. * Open the lid below which the airflow sensor is located and use the potentiome­ter to set it (only by a briefed person). * Tightly set the spiral hose onto the sleeve using the clamp. * Clean and replace the filter as needed. * Replace the activated carbon filter. * Close the filter enclosure with the panel.
  • C
    Connie LaneAug 10, 2025
    What to do if DÜPERTHAL Laboratory Equipment indicates absence of filter?
    • T
      Taylor AshleyAug 10, 2025
      If the error indicates the absence of a filter, install the filter into the enclosure and ensure that the activated carbon filter is correctly positioned with the RFID chip towards the antenna.
  • G
    garciadebraAug 15, 2025
    What to do if DÜPERTHAL 2.00.397-1I Laboratory Equipment doesn't run?
    • J
      John HowardAug 15, 2025
      If the appliance does not run: * Switch the appliance on at the On/Off switch. * Connect the supply cord to the intended socket. * Replace the fuse (1 x 2 A medium slow blow). * Return unit to manufacturer/distributor for check/repair.
  • D
    dsawyerAug 19, 2025
    What to do if DÜPERTHAL 2.00.397-1I Laboratory Equipment LEDs work, but fan does not run?
    • A
      Amanda JordanAug 19, 2025
      If the LEDs are working, but the fan is not running, the issue may be with the fan control. Return the appliance to the manufacturer/ seller for inspection/repair.
  • M
    manuelfieldsAug 26, 2025
    What to do if the fan runs, but the LEDs do not work in DÜPERTHAL Laboratory Equipment?
    • C
      Catherine MooreAug 26, 2025
      If the fan runs but the LEDs do not work, it may be an issue with the LED Electrics/ Electronics. Return the appliance to the manufacturer/ seller for inspection/repair.
  • M
    Michael GonzalezAug 29, 2025
    Why DÜPERTHAL 2.00.397-1I Laboratory Equipment has irregular extraction airflow but no airflow error indicated?
    • A
      Annette StewartAug 29, 2025
      If there is irregular extraction airflow but no airflow error is indicated, the issue may be with the airflow sensor. Open the lid below which the airflow sensor is located and use the potentiome­ter to set it (only by a briefed person).

Summary

Introduction

Explaining Icons Used

Explains safety icons and expressions used in the manual.

Installing and Function Understanding

Intended Use

Details the purpose and limitations of the air extraction monitor.

Occupational Safety

Safety rules for installation and operation with hazardous substances.

Installation and Checkout

Guide for unit connection and preparation for operation.

Monitoring Unit Components

Identifies and describes main components of the monitoring unit.

Operation: Switching On;Off

Explains unit operation, including power on/off procedures.

Setting Pressure Difference

Details adjusting the pressure difference setting for airflow monitoring.

Operation

Normal Operation and Error Alerts

Describes normal status and error indications via unit indicators.

Filter Checking, Replacement, and Documentation

Guidelines for periodic filter inspection, replacement, and documentation.

Potential-free Dry Contact

Explains the function and use of the potential-free contact for error signaling.

Status and Warning Messages via LEDs

Interprets LED indicators for unit status, warnings, and required actions.

Filter Operation and User Obligations

Details filter system, user responsibilities, and safety during filter handling.

Particulate Filter Information

Covers Stage 1 filter, particulate filter servicing, replacement, and disposal.

Particulate Filter Technical Specifications

Provides detailed technical specifications for the particulate filter.

Stage 2 Filter: Activated Carbon

Introduces Stage 2 filter (activated carbon) and its compatibility list.

Activated Carbon Filter Servicing and Replacement

Guides on servicing and replacing the activated carbon filter.

Activated Carbon Filter Disposal

Instructions for disposing of used activated carbon filters.

Activated Carbon Filter Technical Specifications

Lists detailed technical specifications for the activated carbon filter.

Filter Checking (3-Month Interval)

Procedure for checking filters every three months.

Filter Replacement (Annual)

Instructions for annual replacement of both particulate and carbon filters.

Filter Service;Replacement Alerts

Explains unit alerts for filter service and replacement intervals.

Exhaust Air Monitor Technical Specifications

Troubleshooting

Contact Details

Appendix: Compatible Substances

DÜPERTHAL 2.00.397-1I Specifications

General IconGeneral
BrandDÜPERTHAL
Model2.00.397-1I
CategoryLaboratory Equipment
LanguageEnglish