EasyManua.ls Logo

Dura Heat GFA60A User Manual

Dura Heat GFA60A
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.
CONSUMER: Retain this manual for future reference.
Printed in China IMLPFDH - GDB
USER’S MANUAL AND OPERATING INSTRUCTIONS
PROPANE
CONSTRUCTION HEATER
GFA40 (40,000 BTU/HR, FORCED - AIR)
GFA50A (30,000/50,000 BTU/HR, FORCED - AIR)
GFA60A (30,000/60,000 BTU/HR, FORCED - AIR)
GFA100A (70,000/100,000 BTU/HR, FORCED - AIR)
GFA125A (70,000/125,000 BTU/HR, FORCED - AIR)
GFA150A (120,000/150,000 BTU/HR, FORCED - AIR)
DURAHEAT
MODELS:
C US
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
Made by
World Marketing of America, Inc.
PO Box 192, 12256 William Penn Hwy.
Mill Creek PA 17060-0192
(Tel) 1-800-776-9425
www.worldmkting.com

Questions and Answers:

Dura Heat GFA60A Specifications

General IconGeneral
ModelGFA60A
Heating Capacity60, 000 BTU
ThermostatYes
Coverage Area1, 500 sq ft
Weight50 lbs
Fuel TypePropane
IgnitionElectronic
TypeGas Forced Air Heater

Summary

USER'S MANUAL AND OPERATING INSTRUCTIONS

GENERAL HAZARD WARNING

Critical safety warnings for operation, potential for severe injury or death. Must be followed.

DURAHEAT PROPANE FORCED AIR CONSTRUCTION HEATERS

SPECIFICATIONS

Detailed technical specifications for different heater models, including input rating, gas type, and consumption.

GENERAL SAFETY INSTRUCTION

IMPORTANT SAFETY INSTRUCTION

Crucial safety guidelines to prevent accidents, fire, explosion, and injury during operation and maintenance.

UNPACKING HEATER

INFORMATION ON SIZE * CAPACITY OF PROPANE GAS CYLINDERS

INSTALLATION TO THE PROPANE GAS TANK

REFILLING THE PROPANE GAS TANK

Procedures for safely refilling propane gas cylinders, including necessary purging steps before first use.

PROPANE SAFETY

LEAK CHECKING

Method for checking gas connections for leaks using a soap solution to ensure a safe and secure setup.

LIGHTING INSTRUCTIONS

Detailed steps for safely igniting the heater's burner, including pre-ignition checks and burner ignition sequence.

SHUTDOWN INSTRUCTIONS

TEST FIRING HEATER

Guidance on initial test firing of the heater to ensure proper operation and leak checks.

STORAGE

Recommendations for safely storing the heater and propane tanks, emphasizing ventilation and outdoor storage.

MAINTENANCE INSTRUCTIONS

Guidelines for routine maintenance, cleaning, and annual inspection by a qualified technician.

REPLACEMENT PARTS

Information on ordering and using only original, design-specific replacement parts to ensure safety and warranty coverage.

TROUBLESHOOTING

WIRING DIAGRAMS

REPLACEMENT PARTS LIST

PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN

WARRANTY

LIMITED WARRANTY

Defines the duration, coverage, and conditions of the manufacturer's warranty for defects in materials and workmanship.

DUTIES OF THE OWNER

Outlines the owner's responsibilities for operating, maintaining, and documenting the heater for warranty validation.

WHAT IS NOT COVERED

Lists specific conditions and damages that are excluded from warranty coverage, such as misuse or lack of maintenance.

CLAIMS HANDLED AS FOLLOWS

Provides the procedure for initiating and processing warranty claims, including contacting the retailer or manufacturer.

WARRANTY REGISTRATION

Related product manuals