EasyManua.ls Logo

Dura Heat GFA60A - User Manual

Dura Heat GFA60A
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.
CONSUMER: Retain this manual for future reference.
Printed in China IMLPFDH - GDB
USER’S MANUAL AND OPERATING INSTRUCTIONS
PROPANE
CONSTRUCTION HEATER
GFA40 (40,000 BTU/HR, FORCED - AIR)
GFA50A (30,000/50,000 BTU/HR, FORCED - AIR)
GFA60A (30,000/60,000 BTU/HR, FORCED - AIR)
GFA100A (70,000/100,000 BTU/HR, FORCED - AIR)
GFA125A (70,000/125,000 BTU/HR, FORCED - AIR)
GFA150A (120,000/150,000 BTU/HR, FORCED - AIR)
DURAHEAT
MODELS:
C US
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
Made by
World Marketing of America, Inc.
PO Box 192, 12256 William Penn Hwy.
Mill Creek PA 17060-0192
(Tel) 1-800-776-9425
www.worldmkting.com

Questions and Answers

  • E
    Eric CooperJul 28, 2025
    Why does my Dura Heat GFA60A Gas Heater quit while running?
    • E
      Eric BuchananJul 28, 2025
      If your Dura Heat Gas Heater stops running, it could be due to several reasons. The internal temperature might be too high, causing the limit switch to shut down. Ensure the heater's output isn't restricted by obstructions. Another potential cause is a damaged control valve, which would require replacement. Lastly, a buildup of dust or debris inside the heater can cause it to quit; cleaning the inside of the heater might resolve the issue.
  • R
    rachel63Aug 4, 2025
    What to do if Dura Heat GFA60A Gas Heater will not fire?
    • H
      Henry FernandezAug 4, 2025
      If your Dura Heat Gas Heater won't fire, it could be due to a few reasons: * There might be no spark at the ignitor. Check the ignitor wire, reattach or tighten it if loose, and inspect the spark module, replacing it if necessary. * The spark gap might be improper; set the gap according to the specifications. * The electrode could be bad; replace the spark plug.
  • A
    Amy ReedAug 9, 2025
    Why Dura Heat GFA60A Gas Heater fan does not turn on?
    • B
      benjamin36Aug 9, 2025
      If the fan in your Dura Heat Gas Heater doesn't turn when you connect it to an electrical outlet, there are several potential causes: 1. **No electric power**: Ensure the outlet has power. 2. **Fan blade obstruction**: Make sure the housing isn't damaged and that there are no obstructions to the fan. 3. **Bent fan blades**: Straighten the blades to match the others. 4. **Defective fan motor**: Replace the motor.
  • G
    Gwendolyn MurilloAug 15, 2025
    What to do if Dura Heat GFA60A Gas Heater is clicking while the heater is lit?
    • M
      Marvin FletcherAug 16, 2025
      The Dura Heat Gas Heater clicking while lit requires no corrective action.
  • N
    nicholaswalkerAug 21, 2025
    What to do if Dura Heat GFA60A Gas Heater control dial is off and unit is clicking?
    • S
      Shannon GriffinAug 21, 2025
      No corrective action is needed if the control dial is off and the Dura Heat Gas Heater is clicking.

Summary

USERS MANUAL AND OPERATING INSTRUCTIONS

GENERAL HAZARD WARNING

Critical safety warnings for operation, potential for severe injury or death. Must be followed.

DURAHEAT PROPANE FORCED AIR CONSTRUCTION HEATERS

SPECIFICATIONS

Detailed technical specifications for different heater models, including input rating, gas type, and consumption.

GENERAL SAFETY INSTRUCTION

IMPORTANT SAFETY INSTRUCTION

Crucial safety guidelines to prevent accidents, fire, explosion, and injury during operation and maintenance.

UNPACKING HEATER

INFORMATION ON SIZE * CAPACITY OF PROPANE GAS CYLINDERS

INSTALLATION TO THE PROPANE GAS TANK

REFILLING THE PROPANE GAS TANK

Procedures for safely refilling propane gas cylinders, including necessary purging steps before first use.

PROPANE SAFETY

LEAK CHECKING

Method for checking gas connections for leaks using a soap solution to ensure a safe and secure setup.

LIGHTING INSTRUCTIONS

Detailed steps for safely igniting the heater's burner, including pre-ignition checks and burner ignition sequence.

SHUTDOWN INSTRUCTIONS

TEST FIRING HEATER

Guidance on initial test firing of the heater to ensure proper operation and leak checks.

STORAGE

Recommendations for safely storing the heater and propane tanks, emphasizing ventilation and outdoor storage.

MAINTENANCE INSTRUCTIONS

Guidelines for routine maintenance, cleaning, and annual inspection by a qualified technician.

REPLACEMENT PARTS

Information on ordering and using only original, design-specific replacement parts to ensure safety and warranty coverage.

TROUBLESHOOTING

WIRING DIAGRAMS

REPLACEMENT PARTS LIST

PROPANE CONSTRUCTION HEATER ILLUSTRATED; PARTS BREAKDOWN

WARRANTY

LIMITED WARRANTY

Defines the duration, coverage, and conditions of the manufacturer's warranty for defects in materials and workmanship.

DUTIES OF THE OWNER

Outlines the owner's responsibilities for operating, maintaining, and documenting the heater for warranty validation.

WHAT IS NOT COVERED

Lists specific conditions and damages that are excluded from warranty coverage, such as misuse or lack of maintenance.

CLAIMS HANDLED AS FOLLOWS

Provides the procedure for initiating and processing warranty claims, including contacting the retailer or manufacturer.

WARRANTY REGISTRATION

Dura Heat GFA60A Specifications

General IconGeneral
ModelGFA60A
Heating Capacity60, 000 BTU
ThermostatYes
Coverage Area1, 500 sq ft
Weight50 lbs
Fuel TypePropane
IgnitionElectronic
TypeGas Forced Air Heater

Related product manuals