Black plate (53,1)
DURAMAX Diesel Engine (LML/LGH) - 2011
Driving and Operating 9-53
Programmable
Parameters
Factory Setting Minimum Value Maximum Value
PTO Set Speed 1 1250 RPM
500 RPM PTO Set Speed 1
cannot be set below PTO
Standby speed
3100 RPM
PTO Set Speed 2 1700 RPM
500 RPM PTO Set Speed 2
cannot be set below PTO
Standby speed
3100 RPM
Maximum Operating Speed 2100 RPM 500 RPM 3100 RPM
Tap Step 100 RPM 4 RPM 500 RPM
Ramp Rate 200 RPM 4 RPM 1000 RPM
Maximum Vehicle Speed 129 km/h (80 mph) 30 km/h (18 mph) 129 km/h (80 mph)
Minimum Remote
Accelerator Voltage
0.25 V 0.0 V 2.5 V
Maximum Remote
Accelerator Voltage
4.75 V 2.5 V 5.0 V