* Advised pool volume for an entirely insulated pool, with cover, free from wind and exposed to the sun.
UNIT DURA+18i DURA+20i
Advised Pool Volume* m
3
50 - 85 60 - 100
Operating Air Temperature °C -10 ~ 43
Available Operation Mode Heating & Cooling
Air 27°C / Water 26°C / Humidity 80%
Heating Capacity kW 2,5 - 17,8 3,5 - 20
Btu 8530 - 60736 11942 - 68243
Consumed Power kW 0,151 - 2,78 0,214 - 3,07
COP 16,5 - 6,4 16,3 - 6,5
Air 15°C / Water 26°C / Humidity 70%
Heating Capacity kW 2,3 - 12,8 2,5 - 14,7
Btu 7848 - 43675 8530 - 50158
Consumed Power kW 0,353 -2,66 0,357 - 3,19
COP 6,5 - 4,8 7 - 4,6
Air 10°C / Water 26°C / Humidity 64%
Heating Capacity kW 2,0 - 9,8 2,6 - 11,3
Btu 6824 - 33439 8872 - 38557
Consumed Power kW 0,40 - 2,80 0,58 - 3,32
COP 4,9 - 3,5 4,5 - 3,4
Power Supply 230V / 50Hz / 1 Phase
Casing Type Aluminium-alloy
Electronic Controller Duralink
TM
ready with colour LCD
Nominal Running Current A 12,94 13,2
Max. Current A 13,13 13,5
Condensor Titanium Heat Exchanger
Compressor Quantity 1
Compressor Type Rotary - Mitsubishi DC Inverter
Refrigerant R32 (HFK-32)
Refrigerant weight kg 0,65 0,80
GWP 675
CO
2
equivalent 0,439 0,54
Fan Quantity 1
Fan Motor Type DC Brushless
Fan Power Input W 75 75
Fan Rotary Speed RPM 500 - 750 500 - 750
Air Flow m
3
/h 2700 - 3200 4300 - 5000
Fan Direction Horizontal both sides
Noise at 10m dB(A) 20 - 30 21 - 31
Water Connection mm 50
Nominal Water Flow m
3
/h 5,3 6,6
Water Pressure Drop (max): kPa 3 4
Unit Net Dimensions (L*W*H) mm See the drawing of the units
Unit Shipping Dimensions (L*W*H) mm See package label
Net Weight kg See nameplate
Shipping Weight kg See package label
Additional information:
This product contains a uorinated greenhouse gas.
The refrigerant in the product is hermetically sealed.