11 Combustion cycles
This section describes the cycles the pellet stove goes through during the various
combustion phases and which parameters are addressed.
Preheating/cleaning
During this phase, the glow plug starts to glow
and the combustion pot is cleaned
Time par. 29/30
Supplying pellets/oxygen
During this phase, pellets are added until fire is
measured in the combustion pot.
Time par. 40
Pellet supply position par. 25
Blower par. 55
Stabilisation
Once the flue gas temperature has risen (delta T),
the stove enters its stabilisation phase and fewer
pellets are added.
Delta T °C par. 35
Stabilisation time par. 59
Stabilisation power par. 107
In operation
The pellet stove is now in operation. Once the
maximum flue gas temperature is reached, the
pellet supply switches back to positions (P4
through P1).
Pellet supply par. 1-5
Space fan par. 8-12
Blower par. 14-18
Max. flue gas temperature °C par.
20-24
Cleaning
During cleaning, the combustion pot is blown
clean.
Time cycle par. 33-34
Time cleaning par. 31-32
Pellet supply position par. 26
In operation
Switching off
During cooling, the temperature drops to the set
temperature. After that, the blower still runs
after the set time.
Temp. Cool down °C par. 36
Cleaning time min. par. 37
Flue gas vent. stand par. 42