Page 33 of 43
11 Combustion cycles
This section describes the cycles the pellet stove goes through during the various
combustion phases and which parameters are addressed.
During this phase, the glow plug starts to glow
and the combustion pot is cleaned
During this phase, pellets are added until fire is
measured in the combustion pot.
Pellet supply position par. 25
Once the flue gas temperature has risen (delta T),
the stove enters its stabilisation phase and fewer
pellets are added.
Stabilisation time par. 59
Stabilisation power par. 107
The pellet stove is now in operation. Once the
maximum flue gas temperature is reached, the
pellet supply switches back to positions (P4
through P1).
Max. flue gas temperature °C par.
20-24
During cleaning, the combustion pot is blown
clean.
Pellet supply position par. 26
During cooling, the temperature drops to the set
temperature. After that, the blower still runs
after the set time.
Temp. Cool down °C par. 36
Cleaning time min. par. 37
Flue gas vent. stand par. 42