4.4 VS 1200 S
Electrical data 7138-02 7138-03
Rated voltage V 230, 3~ 400, 3~ 230, 3~ 400, 3~
Mains frequency Hz 50 60
Nominal current
A 6.5 3.8 6.8 3.9
Start-up current A ~ 43 ~ 25 ~ 30 ~ 17
Motor protection * A 6.3 4.0 6.3 4.0
Type of protection IP 24
Protection class I
* Max. permitted setting
Connections
Suction connection (outside)
mm
Æ 50
Exhaust air connection (external)
mm
Æ 50
Drain connection, DürrConnect
mm
Æ 20
Media
Max. flow rate with unimpeded flow l/min 2400 2900
Auxiliary air valve setting * mbar/hPa -170 -135
Max. rate of flow of fluids l/min 24
Max. suction height cm 80
* The pressure in the suction system is limited by the supplied auxiliary air valve. The auxiliary air
valve is adjusted to the suction unit and must not be altered.
General data
Max. number of users 4 4
Duty cycle % 100
Dimensions (H x W x D) cm 52 x 41 x 43
Weight, approx. kg 28
Noise level * ca.
without housing
with housing
dB(A)
dB(A)
65
61
69
65
* Noise level in accordance with ISO 3746
Ambient conditions during storage and transport
Temperature °C -10 to +60
Relative humidity % < 95
Ambient conditions during operation
Temperature °C +10 to +40
Product description
16 9000-606-79/30 1912V003
EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Durr Dental VS 900 S and is the answer not in the manual?

Durr Dental VS 900 S Specifications

General IconGeneral
BrandDurr Dental
ModelVS 900 S
CategoryWater Pump
LanguageEnglish

Related product manuals