EasyManua.ls Logo

Dyna APECS 70025 - Magnetic Pickup Installation; Governor Control Box Installation

Default Icon
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual 36532 DYNA 70025 Integrated Actuator
4 QCC LLC
Magnetic Pickup Installation
Refer to Manual 36535.
Governor Control Box Installation
CAUTION: Make certain that proper voltage (12 or 24 Vdc) governor control
box and integrated actuator assembly are used.
1. Wire and pre-set the adjustments of the integrated governor system as
described in the wiring and calibration information for the controller’s
specific part number. Make certain to use the shielded wire and the
twisted cables as shown in the installation information. Connect actuator
wires to the two center terminals on the terminal strip. Do not connect any
other wires to the actuator than the ones from the governor control box.
2. The mechanical governor is to be set 12% higher than the desired
running speed. Calculate the maximum speed setting for the mechanical
governor as follows:
EXAMPLE: If desired speed is 1800 RPM for electronic governing, then
1800 x 0.12 = 216 RPM: 1800 + 216 = 2016 RPM.