EasyManua.ls Logo

DYNACO Dynalogix II - Input Wiring and Terminal Functions

DYNACO Dynalogix II
12 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inputs
DYNACO USA, INC, 11 The Leader in Door Safety & Design
Input 7: Typically used for the open button on a three position switch.
Input will strictly open the door when activated.
Input 8: Typically used for the close button on a three position switch.
Input will strictly close the door when activated.
Input 9: Used for emergency stop or to stop door from being activated. Also
can be wired as the stop button in a three position switch.
Input 10: Used by DYNACO USA Inc. for optional operations ordered with
Dynaco door.
Remote E-stop
N/C Contact
(Jumper)
24 VAC +
1
24 VAC +
1
24 VAC +
1
24 VAC +
1
24 VAC +
1
24 VAC -
X2
24 VAC -
X2
Input 2
2
Input 2
2
Input 3
3
Input 4
4
Input 7
7
Input 8
8
Input 9
9
Input 9
9
Pull cord / push button
N/O contact
Motion sensor / Loop
N/O Contact
Reversing Edge
N/O Contact
Open
N/O Contact
Close
N/O Contact
Stop
N/C Contact
Figure 5.0-2: Basic Input Wiring