EasyManua.ls Logo

Dynaset HG 3,5 - User Manual

Dynaset HG 3,5
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HYDRAULIC GENERATORS
USER MANUAL
HG 3,5
HG 4,1
HG 5
HG 6,5
HG 6,6
HG 10
HG 10,1
HG 12
HG 12,1
HG 15,1
HG 20,1
HG 26
HG 30,1
HG 35
HG 45
HG 55
HG 65
HG 80
Download PDF version from www.Dynaset.com
09/21
rev 1.3

Table of Contents

Questions and Answers

  • B
    Brian BentonAug 16, 2025
    Why does my Dynaset Portable Generator consume an abnormal amount of hydraulic fluid?
    • T
      Tony StephensAug 16, 2025
      If your Dynaset Portable Generator is consuming an abnormal amount of hydraulic fluid, this could be due to a failure of the axial sealing of the generator's hydraulic motor, indicated by hydraulic oil outflow from ventilation grids. Rebuild the return line (T), ensuring the maximum allowed pressure in the return line does not exceed 5 bar, and replace the axial sealing of the generator’s motor. Alternatively, it could be due to oil leakage from the hydraulic motor, indicating it is worn out and needs replacement.
  • P
    Patricia BarnesAug 19, 2025
    What to do if my Dynaset Portable Generator has low output voltage at load?
    • J
      Justin SmithAug 19, 2025
      If your Dynaset Portable Generator has low output voltage at load, it might be overloaded. Reduce the load and check the current I (A) to ensure that the proper load is being applied.
  • K
    Keith ButlerAug 22, 2025
    How to fix output voltage instability in Dynaset HG 3,5 Portable Generator?
    • J
      jennifer27Aug 22, 2025
      If you are experiencing output voltage instability with your Dynaset Portable Generator, check the generator's hydraulics, including the automatic frequency control valve, and make adjustments if necessary. Also, check that the hydraulic oil flow is constant. Ensure that the hydraulic fluid flow and pressure are not excessive, adjusting when necessary. Finally, check the hydraulic motor for possible leakage and replace it if necessary.
  • E
    edwardschristinaAug 26, 2025
    How to stop abnormal noise from Dynaset HG 3,5?
    • L
      Lori RichardsonAug 26, 2025
      If your Dynaset Portable Generator is producing abnormal noise, this could be due to bearing failure. In this case, replace the broken/worn bearing. Another possible cause is a broken fan, which would also need to be replaced.
  • C
    christinasilvaAug 28, 2025
    What to do if Dynaset HG 3,5 output voltage is less than 20Vac?
    • M
      Maureen LarsonAug 28, 2025
      If your Dynaset Portable Generator has output voltage less than 20Vac, it could be due to several reasons. The excitation rectifier might have failed, in which case you should trace the failure and replace the rectifier. (with Compound or Capasitor voltage regulator). Another cause could be a failure of the voltage regulator; in this case, replace the capacitor (HG3,5 ... HG5,0). You may also need to check and adjust the air gap of the compound regulator, replacing it if broken, or check, adjust, or replace the electronic regulator (HG with AVR). Finally, insufficient residual magnetism could be the cause; use an external 12 V DC battery for 1 - 2 seconds to magnetize the rotor (HG3,5 ... HG5,0).
  • J
    jacksonjessicaAug 31, 2025
    Why am I getting a mild electric shock from my Dynaset HG 3,5?
    • J
      Jason DavisAug 31, 2025
      If your Dynaset Portable Generator is producing a mild electric shock, it is likely due to poor hydraulic generator grounding. Ensure proper grounding cable installation.
  • B
    Brenda RiveraSep 3, 2025
    How to troubleshoot low frequency at no load on a Dynaset Portable Generator?
    • A
      Alexandria MartinSep 3, 2025
      If your Dynaset Portable Generator has a low frequency at no load, it could be due to too low rotation speed, which may indicate a hydraulic system failure. Check whether the hydraulic flow and pressure are sufficient, and adjust the RPM-cartridge if necessary. Also, check the hydraulic motor for possible leakage and replace the motor if needed.
  • T
    Theresa CastroSep 6, 2025
    What causes high frequency at load in a Dynaset HG 3,5?
    • R
      roy71Sep 6, 2025
      If your Dynaset Portable Generator has a high frequency at load, it could be due to too high rotation speed, which may indicate a hydraulic system failure. Check whether the hydraulic flow and pressure are sufficient, and adjust the RPM-cartridge if necessary.
  • O
    Omar CookSep 9, 2025
    Why does my Dynaset Portable Generator consume abnormal hydraulic pressure at no load?
    • J
      Jessica FinleySep 9, 2025
      If your Dynaset Portable Generator consumes abnormal hydraulic pressure at no load, it is likely due to a winding failure. One or more stator windings may be in a short circuit, requiring you to replace the generator.
  • J
    Jennifer MahoneySep 12, 2025
    How to fix low output voltage at no load on Dynaset HG 3,5?
    • M
      melissa72Sep 12, 2025
      If your Dynaset Portable Generator has low output voltage at no load, it could be due to poor contact in the electric system. Check all internal contacts and wirings of the generator, and inspect and clean the brushes and slip ring.

Dynaset HG 3,5 Specifications

General IconGeneral
BrandDynaset
ModelHG 3, 5
CategoryPortable Generator
LanguageEnglish

Related product manuals