Overview of the Dynatron Solaris Plus Series devices and their capabilities.
Explains the user-friendly front panel design and intuitive interface for easy treatment setup.
Explains how the device measures and limits output current, including warnings and error messages.
Describes how error messages appear on the screen and how to identify and resolve them.
Provides a step-by-step guide for quickly setting up Interferential or Premodulated treatments.
Offers a comprehensive guide for customizing Interferential and Premodulated treatment parameters.
A concise guide for setting up Biphasic or Russian stimulation treatments.
Detailed instructions for customizing Biphasic and Russian treatment parameters like mode, time, and ramp.
Step-by-step instructions for using the MultiStim probe for Microcurrent treatments.
A straightforward guide to setting up a Tri-Wave Light Therapy treatment quickly.
Instructions on entering parameters for soundhead optimization to ensure proper output.
Introduces the Comboplus feature for flexible combination treatments with Ultrasound and electrotherapy.
Explains how to deliver electrotherapy current through the Ultrasound soundhead for combined treatments.
Step-by-step guide for setting up a COMBO treatment combining Ultrasound and electrotherapy.
Critical safety warnings to follow before and during treatment setup.
Details safety warnings related to TENS device usage, pregnancy, and central pain origin.
Lists contraindications for Tri-Wave Light treatments, including cancer and direct irradiation.
Details precautions for Tri-Wave Light use, including radiation exposure and cleaning procedures.
Outlines a schedule for technician-performed maintenance, including lead and ultrasound calibration.
Instructions on how to update the Solaris Plus device software using an SD card.
Explains the necessity and procedure for routine Ultrasound calibration checks.
Guides the user on saving custom treatment settings as new defaults.
Instructions on how to reset all modality settings back to the original factory defaults.
Describes how to test leads using the console's "Lead Test" function for proper working condition.
Explains how to test carbon pads using a DMM for resistance breakdown.
Details specific procedures for final quality checks, assembly, calibration, and testing.