helpline manual
19
Turbine head brush bar not operating
The brush bar will stop rotating if it becomes obstructed. The brush bar will operate immediately, once the obstruction is cleared.
Press the release catch and remove the
turbine head.
Ask the customer to check the suction
on the end of the wand handle. If
weak go to section 4 on p.16, if strong
continue with these checks.
Undo end cap with a coin. Pull the brush bar out from the turbine
head.
Using scissors, if necessary, carefully
cut away any hair or threads from the
brush bar.
Check the turbine duct for blockages. Reassemble brush bar and end cap.
1
5
6
4
9
8
7
Ask the customer to plug machine in
and test that brush bar is spinning and
the plunger is working. If not working
send new turbine head.
2
3
Check inlet plunger for dust/debris.
Check inlet seal for damage.

Other manuals for Dyson DC26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dyson DC26 and is the answer not in the manual?

Dyson DC26 Specifications

General IconGeneral
Suction power160 AW
Maximum input power- W
Annual energy consumption- kWh
Proper useHome
Noise level- dB
Removable filterYes
Cleaning surfacesCarpet, Hard floor
Vacuum air filteringHEPA
Dirt separating methodFiltering
TypeCylinder vacuum
CordlessNo
Cleaning typeDry
Dust capacity- L
Product colorBlue, Transparent
Tube materialThe material the tube is made of.
Dust container typeBagless
Cord length5 m
Dust capacity dry0.68 L
Vacuum brushes includedHard floor brush
Weight and Dimensions IconWeight and Dimensions
Weight5200 g

Related product manuals