3
Table 2 FO 24 BB FO 24 HB FO 24 HM FO 28 HM Unit
Gas Category*
Boiler Type
Type of gas
Performances
P
min
, Min. Heat Output
P
maks
, Max. Heat Output
P
%80
, Heat Output
Q
min
, Min. Thermal Load
Q
maks
, Max. Thermal Load
Q
%80
, Thermal Load
Gas Consumption**
Natural Gas (Max. Load)
Natural Gas (Min. Load)
LPG
Gas Supply Pressure
Natural Gas
LPG
Domestic Hot Water
Min. Flow Rate For Activating***
Max. Flow Rate
Min. Operating Pressure
Max. Operating Pressure
Set Temperature Range
Central Heating
Min. Operating Pressure
Max. Operating Pressure
Set Temperature Range
General
Electrical Supply
Electrical Power Consumption
Expansion Vessel
Dimensions (HxWxL)
Weight (Net)
II
2H 3+
B
11 BS
Natural gas
LPG
8,4
24
19,2
9,3
26,6
21,3
2,77
0,97
2,08
20
28 / 37
3
10 (t=34)
0,3
10
35-60
0,8
3
40-80
230V AC- 50Hz
105
8
750x454x340
33,7
II
2H 3+
C
12x
, C
32
Natural gas
LPG
8,4
24
19,2
9,2
26,2
21
2,73
0,96
2,08
20
28 / 37
3
10 (t=34)
0,3
10
35-60
0,8
3
40-80
230V AC- 50Hz
150
8
750x454x340
39,8
II
2H 3+
C
12x
, C
32
Natural gas
LPG
8,4
24
19,2
9,2
26,2
21
2,73
0,96
2,08
20
28 / 37
3
10 (t=34)
0,3
10
35-60
0,8
3
40-80
230V AC- 50Hz
150
8
750x454x340
40,8
II
2H 3+
C
12x
, C
32
Natural gas
LPG
9,8
28
22,4
10,7
30,6
24,5
3,19
1,12
2,39
20
28 / 37
3
12 (t=33)
0,3
10
35-60
0,8
3
40-80
230V AC- 50Hz
150
8
750x454x340
41,3
kW
kW
kW
kW
kW
kW
m
3
/h
m
3
/h
kg/h
mbar
mbar
ltr/min
ltr/min
bar
bar
o
C
bar
bar
o
C
V AC/Hz
watt
ltr
mm
kg
**For gas consumption calculation ; Natural gas: Hu=9,59 kWh/m
3
LPG: Hu=12,793 kWh/kg
*** DHW ON flow rate can be adjustable as 3 ltr/min (default) or 3,5 ltr/min.
*the following gas categories can also be used
FO 24 BB
FO 24 HB FO 24 HM FO 28 HM
Gas Categories
II
2H 3B/P
II
2E 3B/P
II
2H 3B/P
II
2E 3B/P
II
2H 3B/P
II
2E 3B/P
II
2H 3B/P
II
2E 3B/P

Related product manuals