WARNING: In case of gas leak, fire or explosion hazard, property damage,
severe injury or death can happen. Therefore, gas leak test
must be performed by qualified person after gas type conversion.
¨
GAS LEAK TEST
¾ Apply a rich soap and water solution to the surface of all pipe connections. Bubbles indicate a
gas leak
¾ In case of gas leak, tighten the pipe connection.
¾ Check the pipe connection again for gas leak.
¾ Replace the part/parts if gas leak can not be stopped.
CAUTION: Keep soap and water solution away from electrical connections during
gas leak test .