EI-1000 & 2000: Setup, Calibration and Troubleshooting.
Page 1 of 19
EI-1000 & EI-2000
DIGITAL WEIGH INDICATOR/TRANSMITTER
EAGLE MICROSYSTEMS, INC.
366 CIRCLE OF PROGRESS
POTTSTOWN, PA 19464

Other manuals for Eagle EI-1000

Questions and Answers

  • T
    Traci MooreAug 25, 2025
    What causes weight readings to drift wildly or show error codes (OL, UL, A-OL) on Eagle Accessories scales?
    • M
      Mary WileyAug 26, 2025
      If the weight reading on your Eagle Accessories device starts drifting wildly or displays OL, UL, or A-OL, try the following: * Inspect the cable connecting the scale to the instrument for any signs of damage. * Check the wiring inside the instrument for loose or broken connections. * If you're using an LP4320, LP4300, or most multiple load cell scales, there's a summing box under the deck. Open it and check for moisture or corrosion, especially if the cable looks fine. * For all scales with a summing box, inspect the connections inside for loose or broken wires. Also, check the cables from the load cells to the summing box for any damage.
  • L
    leejamesAug 30, 2025
    Why isn't the weight reading tracking correctly on my Eagle EI-1000 Accessories scale?
    • D
      Diane WintersAug 31, 2025
      If the weight reading on your Eagle Accessories scale isn't tracking properly, check these items: * Inspect the scale and tank to ensure they are not rubbing against anything. * Verify that all piping connected to the tank has a flexible section to allow for movement. * Check underneath the scale for any obstructions. * Make sure the adjustable feet haven't been backed out so far that they're hitting the underside of the deck.
  • L
    Latoya LeeSep 3, 2025
    What does it mean when my Eagle EI-1000 Accessories display shows 'n0 0' when I press the zero button, and how do I fix it?
    • W
      William HarrisonSep 3, 2025
      If your Eagle Accessories display shows “n0 0” when you press the zero button: The zero button is intentionally limited to prevent accidental zeroing at full scale. If you need to bypass this, access the Calibration section. Enter calibration mode and complete steps 1, 2, 3, and 7. Alternatively, a faster method involves opening the front cover and closing dip switch #4. The gross light(s) will flash. Press the zero button, then open switch #4.
  • M
    Margaret MaldonadoSep 6, 2025
    What to do if my Eagle EI-1000 display stays at zero when pumping chemicals but works with physical weight?
    • A
      amandamillerSep 6, 2025
      If your Eagle Accessories display remains at zero when chemical is pumped into the tank but increases when stepped on or a test weight is applied, turn off the automatic zero function by setting parameter P113 to 'off'. See the Changing Configuration Parameters and day tank setup section for more information.
  • M
    Michael ChoiSep 9, 2025
    Why does my Eagle Accessories EI-1000 display show gibberish?
    • S
      Sarah TaylorSep 9, 2025
      If your Eagle Accessories EI-1000 display is showing gibberish, check J3 as shown above. If you ordered both EI-1000’s and 2000’s you may have accidentally swapped displays.
  • A
    Amanda GarciaSep 10, 2025
    Why is the display very dim on my Eagle EI-1000 Accessories device?
    • K
      Kimberly GibsonSep 12, 2025
      If the display on your Eagle Accessories unit is very dim, there are a few potential causes: * First, unplug the unit and check the S2 setting. If it's set for 230 VAC while you're running it on 115 VAC, this could be the problem. * Second, if S2 is correctly set, disconnect the scale(s) and plug the unit back in. If the display is now bright, there's likely a short in the cable or scale base. Inspect the cable to the scale(s) for any points that may be smashed or pinched during installation. * Third, measure the AC input voltage with a meter to ensure it's not too low.
  • L
    Lisa Jackson MDSep 12, 2025
    What causes the Eagle EI-1000 EI-2000 display to light up the 8 LEDs but not the digits?
    • N
      nathanscottSep 12, 2025
      If the EI-2000 display on your Eagle Accessories device lights up the 8 LEDs but not the digits, the ribbon cable is likely plugged in backwards on one end.
  • E
    Eric GonzalesNov 15, 2025
    How to troubleshoot power issues with my Eagle EI-1000 Accessories instrument?
    • K
      Kimberly WigginsNov 15, 2025
      If your Eagle Accessories instrument isn't powering up, here are a few things to check: * First, examine the ribbon cable between the display and CPU boards. Ensure it's fully plugged in and that the red line is next to the pin 1 markings. * Second, unplug the power and verify that S2 is set to the correct input voltage. Adjust if necessary and plug the unit back in. * Third, use a multimeter to check the voltage at the H and N terminals on TB1. You should see about 115 or 220 volts AC. If there's no voltage, the instrument isn't receiving power. * Fourth, unplug the power and measure the resistance across the plug. An EI set for 115 VAC should read near 70 ohms, and a 230 VAC unit should read near 275 ohms. If not, check the fuse located in the black fuseholder with a slotted scr...
  • M
    Melissa CannonNov 21, 2025
    What to do if my Eagle EI-1000 Accessories scale display stays at zero or shows unstable weight readings?
    • A
      Arthur WilsonNov 21, 2025
      If your Eagle Accessories display stays at zero, shows a slight increase, or gives unstable weight readings when you place a known weight on the scale, consider the following: * For DCS-302 or DS-750 models, check if the shipping nut or bracket has been removed from under the square box, holding the long levers against the deck. * For EDS-400 models, verify that the foam used to secure the long lever during shipping has been removed. * Ensure the foot is on the floor and the bolts mounting the load cell are not touching the floor on scales with a hinge and a load cell mounted on top of the deck. * For EI-1000 with a single scale, confirm the scale is wired to TB4 (seven-position terminal). * The EI-1000 comes with a jumper shorting the +S,-S, and –E terminals on TB5. If it was m...
  • S
    Stephanie RayNov 27, 2025
    How do I fix an incorrect remaining weight reading on my Eagle EI-1000 scale when the gross weight is correct?
    • K
      Kimberly HernandezNov 27, 2025
      If the remaining weight is incorrect but the gross weight is correct on your Eagle Accessories device, here's what you can do: * Press the SELECT button several times to see if you can select the tare weight. If you can, use the UP/DOWN arrows to adjust it. * If you can't access the tare weight directly, select the remaining weight, then hold down the UP arrow. After about three seconds, the unit should jump to the tare weight and start scrolling. Release the button and use the UP/DOWN arrows to set the tare. Press SELECT when finished. * If those steps don't work, you might have an older indicator. To enter configuration mode, close dip switch S1 position 1. Set parameter P001 to "1" to select manual mode. Open the switch, and you should be able to select the tare. Note: On old sty...

Summary

Installation and Wiring

Calibration

Operation in Automatic Modes

Scale Wiring Color Codes

Wiring Color Codes

Table detailing wiring color codes for different terminals.

Orange and Blue Wire Usage

Details specific wiring instructions for orange and blue wires.

Wiring Code Troubleshooting

Steps to take if the selected wiring code does not function.

Troubleshooting

Instrument Power-Up Issues

Diagnosing and resolving issues where the instrument does not power up.

Display Problems

Troubleshooting common display issues like gibberish or dimness.

Zero and Weight Reading Issues

Resolving "n0 0" message and unstable weight readings.

Scale Mechanical and Wiring Issues

Addressing issues related to scale mechanics and wiring.

Changing Configuration Parameters

Turning Off Auto Zeroing

Steps to disable the automatic zero function.

4-20 mA Outputs

Parameter Setup

Setting up parameters for 4-20 mA analog output.

Output Testing

Testing the functionality of the 4-20 mA analog outputs.

Calibration

Calibrating the 4-20 mA analog output points.

4-20 mA Troubleshooting

Troubleshooting Common Issues

Diagnosing and resolving 4-20 mA output problems.

Remote Readout Issues

Troubleshooting problems with the remote readout.

Day Tank Operation

Instrument Setup

Configuring the instrument for day tank applications.

Calibrating an Empty Tank

Procedure for calibrating when the tank is empty.

Calibrating a Non-Empty Tank

Procedure for calibrating a tank that cannot be fully emptied.