General Instructions
Compressors have weather resistant housing, but we strongly suggest that you protect them from the ele-
ments in some way. DO NOT place your compressor in low spots or any place water may puddle. Flooded
compressors are not covered under warranty.
1. Place compressor on level surface above the water level.
2. Compressor must be protected and housed from extreme elements. Place compressor in shaded area
that is free from excessive dust or moisture.
3. Assemble the diusers by threading rubber membrane diusers into provided PVC assembly. Use zip
ties to secure diuser/PVC assembly to plastic underlay. Attach a brick (not included) to the diuser
base to sink assembly to the bottom of the pond.
4. Attach Quick Sink tubing to barbed outlet of diuser assembly and secure with hose clamp.
5. Unroll the tubing and install diuser into pond. This will allow you to trim tubing to length at the com
-
pressor. Lower diusers in the pond where circulation is maximized.
6. Connect the rubber elbow to the compressor with pinch clamps.
7. Connect the end of airline to outlet of the compressor and secure with provided hose clamp. For PA8SW
with a manifold system, connect the manifold to the compressor, then the ends of airline runs to mani
-
fold system and secure with provided hose clamps.
8. Plug compressor into 120v AC GFCI protected outlet.
Shallow Water Pond Aeration Kit Features:
Kit Maximum Compressor Maximum CFM Maximum*
Part # Pond Size Warranty** (cubic feet per minute) Recommended Depth
PA6SW 3/8 Acre 2 Years 2.5 cfm 7 feet
PA8SW 3/4 Acre 2 Years 5.2 cfm 7 feet
Pond shape, depth and condition aect actual maximum pond size.
*Compressors may perform in slightly deeper water, but this is the recommended maximum depth. With deeper water
and longer tubing runs the rubber diaphragms will wear out sooner and require replacement more frequently as a wear
item. For longer tubing runs an increase in the diameter of the tubing may be necessary to be sure the overall maximum
pressure of the compressor is not surpassed.
**See compressor instructions for warranty details
PA6SW
PA8SW
DM4
Diuser Assembly
Use only supplied short section of
tubing to connect compressor to
splitter. Do not use longer tubing.

Related product manuals