Trouble-Shooting.
Problem: The system does not response when transmitter is pressed.
Make sure the transmitter in good condition. Ensure that the battery is
functioning and LED on the transmitter lights up when button is
pressed. Replace transmitter if the LED does not light after new battery
is replaced.
Try any external push buttons or exit buttons. If they activate the gate
but all transmitters do not activate the gate, check receiver wiring to
board.
Check remote DIP switches match the transmitter DIP Switches.
Check the wiring of the receiver panel and make sure the power is
connected in correct polarity. Check also the power to the control board
with the red LED at block1 is ON and the battery has 12V. Ensure
12Vdc is supplied to the receiver box.
Check arm(s) are working using power direct from the battery.
Check wires are connected properly to the control board.
Problem: The gate will open but not close
Check the wire loop is still in place on block 5 between terminal 3 and
4. If beams are fitted, check beam wiring/setup/ obstructions.
Problem: The gate does not fully open and close, or stops half way.
Ensure there is no obstruction to the movement of the gate. This could
also be high resistance such as poor gate installation or high winds
activating the anti-obstruction sensing. This can be verified by releasing
the gate to Emergency release mode. Manual push the gate open and
close to detect any obstruction.
Ensure that on the first setting setup, the gate is fully closed before the
board is initialized. Short distance detection will result in error of count
for the gate opening and closing angle.
Problem: The gate does not travel smoothly when opening or closing.
Ensure there is no obstruction to the movement of the gate such as
hitting the ground. This can be verified by releasing the gate to
Emergency release mode. Manually swing the gate open / close to
detect any tight spots.
Ensure that the gate is properly leveled and that the dimension guide
for the installation of the Automatic gate is followed. Arm must not be
parallel to the gate when fully open or fully closed.
Problem: On double setup one gate closes fully before the 2
nd
gate starts.
System is running on battery only (eg. Solar setup) and transformer AC
not connected. Check power with volt meter.