IB02602004E For more information visit: www.eaton.com
Instructional Literature
Effective: May 2008 Page 5
Instructions for the FP-6000 Protective Relay
FP-6000 Features List
Protection Features
Phase overcurrent
A. 2-stage instantaneous with timers (50P-1 & 50P-2)
B. Inverse time overcurrent (51P)
C. Voltage restraint inverse time overcurrent (51P2)
D. 10 standard curves
E. Reset
1. Instantaneous
2. Time Delay
3. Calculated
Independent measured ground or neutral overcurrent element
A. 2-stage instantaneous with timers (50X-1 & 50X-2)
B. Inverse time overcurrent (51X)
C. 10 standard & 3 user defined custom curves
D. Reset
1. Instantaneous
2. Time Delay
3. Calculated
Independent calculated ground or neutral overcurrent element
A. 2-stage instantaneous with timers (50R-1 & 50R-2)
B. Inverse time overcurrent (51R)
C. 10 standard curves
D. Reset
1. Instantaneous
2. Time Delay
3. Calculated
Breaker failure (50BF)
Phase current unbalance and sequence protection (46)
Phase voltage unbalance and sequence protection (47)
Main 3-phase under/overvoltage (27M1/59M1)
Power Protection (32), Var Protection(32V)
Under/over frequency (81U/81O)
Auxiliary single-phase under/overvoltage (27A1/59A1)
Neutral voltage (59N1)
Power factor (55)
Thermal Protection (49DT, 49MT)
Zone interlocking for bus protection (87B)
Additional elements for alarming on:
A. Instantaneous overcurrent (50P-3, 50X-3, 50R-3)
B. Under/overvoltage (27M-2/59M-2, 27A-2/59A-2)
C. Power (32), Var (32V)
D. Under/over frequency (81U-2, 810-2)
E. Current unbalance (46-2)
F. Voltage unbalance (47-2)
G. Neutral voltage (59N-2)
H. Thermal Alarm (49DA, 49MA)
Metering Features
Amps & amps demand
Volts
Volt-amps
Watts & kW demand
kwh, net kwh
Vars & kvar demand
Kvarh & net kvarh
Power factor
Frequency
Min/max recording
Trending (load profile over time)
Current & voltage THD
RTD
Monitoring Features
Trip coil
Breaker wear (accumulated interrupted current)
Oscillography (256 cycles total, up to 16 events)
Trip data logs (up to 16 events)
Sequence of events report (up to 100 events)
Clock (1 ms time stamping)
Control Functions
Remote open/close
Local open/close
Programmable I/O
Programmable logic gates and timers
Multiple setting groups (up to 4)
Sync-Check (25)
Cold load pickup
Autoreclose Function (79)
Auto Zone Coordination
Mechanical Features
Full drawout unit (automatic CT shorts)
Standard IQ Panel Cutout retrofit possible
Outline Size is approximately 6.5" (165.1 mm) wide 10"
(254 mm) high 7" (177.8 mm) deep
Weight for outer case is 5.0 lbs. (2.27kg), inner drawout
5.8 lbs.(2.63 kg)
Approximate shipping weight is 16.5 lbs. (7.48 kg)
Design Features
Password protected
Data acquisition with necessary resolution and sampling
frequency
A. 3-phase currents
B. Ground current
C. 3-phase voltages
D. Auxiliary voltage
E. rms values (current and voltages)
F. Power [real (W), reactive (VAR), apparent (VA)]
G. Power factor (apparent and displacement)
H. Fequency
I. Power and current demand

Related product manuals