Examples of valid commands are below:
1 @ 1 0 0 Enter
This sets the intensity of channel 1 to 100%.
2 And 3 @ 7 5 Enter
This sets the intensity of channels 2 and 3 to 75%.
5 Thru 1 0 @ 5 0 Enter
This sets the intensity of channels 5 through to 10 to 50%.
5 Thru 1 0 Except 7 @ 6 5 Enter
This sets the intensity of channels 5, 6, 8, 9 and 10 to 65%
3 Thru 9 Except 5 Except 6 @ 0 Enter
This sets the intensity of channels 3, 4, 7, 8 and 9 to 0%. Note how
Except is used twice to exclude two different channels from the range.
1 Thru 3 And 7 Thru 9 @ 2 5 Enter
This sets the intensity of channels 1, 2, 3, 7, 8, and 9 to 25%.
1 And 7 Thru 1 2 Except 9 @ 5 Enter
This sets the intensity of channels 1, 7, 8, 10, 11 and 12 to 5%.
There are also some shortcuts available:
1 @ @
@@ is a shortcut which quickly sets the intensity to 100%.
1 @ .
@ . (at dot) is a shortcut which quickly sets the intensity to 0%.
Enter Enter @ .
Enter Enter is a shortcut which quickly selects all the channels that
are currently on (above 0%). In this example, it then takes them to 0%
using the @. shortcut (resulting in a blackout).