Instructions for Installation, Operation and Maintenance of
Magnum DS, DSX and DSL Low Voltage Power Circuit Breakers
I.B. 2C12060H08 Supersedes I.B. 2C12060H07 dated April 2005
Effective May 2006
IB2C12060H08
For more information visit: www.EatonElectrical.com
www . ElectricalPartManuals . com

Table of Contents

Questions and Answers

  • S
    Sherri WoodardAug 6, 2025
    What to do if the Eaton MDN-616 Power Tool circuit breaker trips open?
    • F
      frodriguezAug 6, 2025
      If the Eaton Power Tool circuit breaker trips open, it could be due to several reasons. First, ensure the rating plug is installed and corresponds to the current sensors. If the breaker trips repeatedly due to transient current, allow the breaker and loads to cool before re-closing. Finally, an overload or fault current condition may be present. Use the status and fault indicators to locate and remove the overload or fault.
  • B
    Barry EvansAug 20, 2025
    Why does my Eaton MDN-616 Power Tool circuit breaker open if the fault trip indicator button is not out?
    • M
      mendozatonyAug 20, 2025
      If your Eaton Power Tool circuit breaker opens and the fault trip indicator button is not out, several factors could be at play. It might be due to undervoltage release operation; in this case, check and correct the UVR supply voltage to be within 85-110% of the rated voltage. Alternatively, the shunt trip may be operating, so check the control signals to the shunt trip and correct if necessary. If neither of these is the cause, the trip latch may be defective, so inspect its condition and engagement before closing.

Summary

SECTION 1: INTRODUCTION

1-1 General Information

Provides general information about Magnum DS, DSX, and DSL circuit breakers.

1-2 Safety Features

Details built-in interlocks and safety features for hazard reduction.

1-3 Safety Practices

Lists essential safety practices for installation, operation, and maintenance.

1-4 Qualified Personnel

Defines qualifications required for operating and maintaining breakers.

SECTION 2: RECEIVING, HANDLING AND INSTALLATION

2-3 Unpacking Circuit Breaker

Provides instructions for safely unpacking circuit breakers.

2-4 Lifting Circuit Breaker

Explains safe lifting procedures for circuit breakers.

2-5 Circuit Breaker Inspection

Outlines visual inspection steps for circuit breakers.

2-6 Installing Drawout Circuit Breaker

Details the process for installing drawout circuit breakers.

2-6.1 Rejection Interlocks

Explains the function and importance of rejection interlocks.

2-6.2 Circuit Breaker Positioning

Describes the four normal positions for drawout circuit breakers.

2-6.3 Levering Circuit Breaker

Details the procedure for levering circuit breakers into position.

SECTION 3: CIRCUIT BREAKER DESCRIPTION AND OPERATION

3-1.1 MDSL Application;Operation

Details the application and operation of MDSL circuit breakers.

3-6 Electronic Tripping System

Describes the three-part electronic tripping system.

3-6.1 Microprocessor-based Trip Unit

Discusses the Digitrip RMS trip units and their features.

3-6.2 Rating Plug

Explains the function and importance of the rating plug.

3-6.3 Current Sensors

Details the installation and function of current sensors.

SECTION 6: INSPECTION AND MAINTENANCE

6-4.1 Functional Field Testing

Describes functional field testing procedures for breakers.

SECTION 7: TROUBLESHOOTING

Eaton MDN-616 Specifications

General IconGeneral
BrandEaton
ModelMDN-616
CategoryPower Tool
LanguageEnglish