113
TRSM0940 Removal and Installation | Electronic Clutch Actuator (ECA)
2. Install the 4 cap screws from the ECA mounting flange.
Tighten them to 35–45 lb-ft (47–61 N•m).
Note: The cap screws for the ECA are longer than the
ECA Bracket cap screws.
Note: Ensure the ECA does not bind on the Cross-Shaft
by snugging all cap screws before tightening to the
specified torque.
3. If applicable, install the 4 cap screws for the ECA
Shield. Tighten them to 35–45 lb-ft (47–61 N•m).
4. Apply NyoGel to terminals and reconnect the 8-way
and 3-way connectors to the ECA.
Note: Apply just enough material to cover the end of
the terminal.
Note: Use only Eaton lubricant part number 5564527
(Nye Lubricants NYOGEL 760G. For MSDS safety or
other information see www.nyelubricants.com.)
5. Reconnect the negative 12-volt battery cable.
6. If previously removed, install the 8-bolt PTO after ECA
installation. Follow the PTO manufacturer’s guidelines
for installation instructions.