LAS/VAS Auxiliary Section Assembly and Installation | Auxiliary Section Service Procedures TRSM0940
16. Install a new gasket on the surface between the Main
Case and the Auxiliary Case.
17. Install the Auxiliary Case assembly onto the Transmis-
sion Main Case dowel pins. Using the Output Shaft,
wiggle the Auxiliary Case forward until it is as far for-
ward as possible. Remove the Auxiliary Section Lifting
Bracket.
18. Push Auxiliary Section flush with the Transmission
Main Case and install cap screws. Torque cap screws
to 40–45 lb-ft.
Note: If Auxiliary Case does not come flush with the
Transmission Main Case with minimal force this could
indicate an issue with Auxiliary gearing timing.
Note: If Auxiliary Section Bearings or gearing were
replaced then the Auxiliary Counter Shaft shimming
procedures will need to be followed.