74
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
2022.10.7
MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly | Auxiliary Section Service Procedures TRSM0940
14. Remove the Auxiliary Counter Shaft Bearing Races
from their bores.
15. If necessary, secure the Countershafts in a vise and
remove both the front and rear bearings from the
shafts with a bearing separator and jaw pullers.
16. Remove the 15/16” cap screw and retainer bolt that
was loosened in step 9
17. Remove the splitter gear from the Output Shaft
Note: For disassembly and assembly of the Splitter
Gear assembly, please refer to the “Splitter Gear Bear-
ing Disassembly and Assembly – MHP, MXP, VHP,
VXP” section