86
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
2022.10.7
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation | Auxiliary Section Service Procedures TRSM0940
11. Apply Eaton Sealant #71205 or equivalent to the retain-
ing cap screws, and install the six (6) cap screws in the
non-chamfered holes. Torque to 35-45 lb-ft
(47.45-61.01N•m).
12. Install the Auxiliary Countershaft Bearing Races.
13. Install each Auxiliary Countershaft Retaining Strap with
2- 3/8” NC x 1” NC and 1 3/8” NC x 2-1/2” clean cap
screws.
Note: Do not use an air gun on strap bolts. Tighten by
hand until cap screws are snug