Power indicator light is illuminated, but the unit is not collecting water.
Check
1. The humidistat (if activated) may be set too lo
w, increase the setting.
2. The water container may be full, empty the container.
3. The unit may have been set to standby mode – check the settings.
4. Ensure the water container is fitted. If you continue to have problems please see ‘Requesting Service’.
Fan operates continuously.
Check
1.
Check that the continuous fan operation is not selec
ted. If you continue to have problems please see ‘Requesting
Service’.
Reduced water extraction.
Check
1. The humidistat (if activated) may be set too lo
w, if signs of condensation or dampness remain, increase the
setting.
2. The filter may be blocked. Remove, clean and refit.
3. After being installed all dehumidifiers will collect less moisture as initial excess moisture is removed. This is
normal.
4. The dehumidifier may be positioned next to a heat source i.e. a radiator – reposition. If you continue to have
problems see ‘Requesting Service’.
Dehumidifier collects water but is not preventing condensation.
Check
1.
The humidistat (if activated) may be set too lo
w, increase the setting.
2. Increase the fan speed to NORMAL if set to QUIET.
3. Outside temperatures have dropped suddenly. The dehumidifier may take a few days to get the problem back
under control.
If you continue to have problems please see ‘Requesting Service’.
If your Ebac 2000 fails to operate