Questions and Answers

  • A
    Alex CastanedaJul 31, 2025
    Why is my Ebac Dehumidifier not collecting water?
    • B
      Bethany AbbottAug 1, 2025
      If your Ebac Dehumidifier isn't extracting water, several factors could be at play. Begin by checking for sufficient airflow. If airflow is not the issue, it could be a compressor fault or a loss of refrigerant gas, in which case you should contact the Factory Service Center.
  • M
    Mrs. Emily Wang DVMAug 6, 2025
    How can I stop my Ebac RM85 10560RG-GB Dehumidifier from leaking water inside?
    • S
      shafferaustinAug 6, 2025
      If you find water flooding inside your Ebac Dehumidifier, it could be due to a few reasons. Check if the drain pipe is blocked or frozen and clear any obstructions. Also, ensure that the drain hose isn't positioned too high, making sure no section is above the water outlet level. Lastly, inspect the tubing for crimps or blockages; straighten, clear, or replace it as needed.
  • C
    Carrie SimonAug 10, 2025
    How to troubleshoot an Ebac RM85 10560RG-GB that won't turn on?
    • J
      James ThomasAug 10, 2025
      If your Ebac Dehumidifier is not turning on, there could be a few reasons. First, check the power from the power supply panel to ensure the unit is receiving electricity. If the power supply is fine, the mains cable might be damaged. In this case, contact the Factory Service Center for assistance.
  • C
    Crystal BarberAug 16, 2025
    What causes defrosting problems in Ebac RM85 10560RG-GB Dehumidifier?
    • J
      Jeanne BrownAug 16, 2025
      If your Ebac Dehumidifier isn't defrosting properly, it could be due to a faulty timer or a faulty by-pass valve. In either case, contact the Factory Service Center for assistance.
  • M
    Mary EvansAug 20, 2025
    What to do if my Ebac Dehumidifier has little or no airflow?
    • D
      Dustin ClarkAug 20, 2025
      If your Ebac Dehumidifier has little to no airflow, several issues could be the cause. The fan motor might be burnt out, requiring a replacement. Alternatively, the refrigeration coils might be dirty, requiring maintenance. Also, loose electrical wiring can be a factor; inspect the wiring diagram to locate and repair any faults.
  • P
    perezanthonyAug 26, 2025
    Why is my Ebac Dehumidifier vibrating so much?
    • C
      crystal36Aug 26, 2025
      Excessive vibration in your Ebac Dehumidifier can stem from a couple of issues. Start by checking if the compressor is loose and tighten the nuts on the compressor mounts. If that's not the problem, the fan might be damaged and need replacement.

Summary

Introduction

Specifications

Operation

Routine Maintenance

Repairs

Troubleshooting

Spare Parts List

Ebac RM85 10560RG-GB Specifications

General IconGeneral
ModelRM85 10560RG-GB
CategoryDehumidifier
BrandEbac
MPN10560RG-GB
RefrigerantR134a
Operating Temperature Range5-35°C
Extraction Rate (30°C 80% RH)85 litres/day