3.7 Settings
P00: it is Reset all parameter Function:
Change the value as 10, then short press the “M” key, the screen will
Display all segment, then all parameter will reset to the original value
P01: Backlight Brightness (1: darkest; 3: brightest)
P02: Mileage Unit (0: KM; 1: MILE)
P03: Voltage Class: 24V /36V / 48V
P04: Hibernation Time (0: never, other figures refer to the hibernation time)
Unit: Minute
P05: Power Gear – 0/3 Gear Mode: Gear
1/5 Gear Mode: Gear
P06: Wheel Diameter Unit: inch Precision: 0.1
P07: Magnet Steel Number for Speed Test Range: 1-100
P08: Speed Limit
Range: 0-50km/h, parameter 50 indicates no speed limit.
P09: Zero / Non-zero Start Setting:
0: Zero Start
1: Non-zero Start
P10: Drive Mode Setting
0: Power Drive – The specific gear of the assist drive decides the assist power
value. In this status the handlebar does not work.
1: Electric Drive – The vehicle is driven by the handlebar. In this status the power
gear does not work.
2: Power Drive + Electric Drive – Electric drive does not work in zero-startstatus.
P12: Assist Power Intensity Range: 0-5
P13: Power Magnet Steel Number:
P16: ODO Zero-Out: Long press the upper key for 5 seconds and ODO will zero out.
4