INSTALLATION INSTRUCTIONS
HIGH PRESSURE PUMP UNIT
Mount the high pressure pump/motor unit horizontally in a dry and ventilated location. Maximum ambient
temperature for continuous duty is 40˚C / 104˚F.
CAUTION: Motor gets hot during prolonged operation.
PRESSURE VESSEL (MEMBRANE HOUSING)
Mount the pressure vessel(s) with the provided brackets vertical (with the flow upwards) or horizontal
in a convenient location away from the heat of the engine as close as possible to the high pressure
pump.
The membrane is sealed within its housing by plugs at both ends. Inside the housing is a small amount
of preservative to keep the membrane moist and prevent bacterial growth. The shelf life of the
preservative, under best conditions, is one year.
When all other components and hoses/tubes are completely assembled, remove the caps on the high
pressure fittings and the sealed tube from the product water outlet on the membrane housing/s and
then finish making all final hose/tube connections. This will insure that the membrane is kept moist.
CONTROL PANEL
Mount the control panel preferable trough a bulkhead or on any panel in an easily accessible
location as close as practical to the membrane housing(s).