EasyManuals Logo

Echo ES-210 User Manual

Echo ES-210
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
SHRED 'N' VAC
®
OPERATOR'S MANUAL
ASSEMBLY
WARNING DANGER
Never perform maintenance or assembly procedures with engine
running, or serious personal injury may result.
BLOWER APPLICATION
Install Blower Pipes
1. Align grooves in straight pipe with pegs on blower housing and
slide pipe onto housing.
2. Turn straight pipe clockwise to lock into place.
3. Align grooves in fan head nozzle with pegs on straight pipe and
slide fan head nozzle onto straight pipe.
4. Turn fan head nozzle clockwise to lock into place.
VACUUM/SHREDDING APPLICATION
Install Vacuum Tube and Bag Assembly
1. Turn knob (A) counter clockwise until hinged housing cover is
free to open for vacuum tube installation.
2. While holding housing cover open. Install vacuum tube into
blower housing with bevel end facing downward and secure
vacuum tube with clamp (B). Clamp fits under slotted guides (C).
NOTE
Engine will not start/operate unless safety interlock switch (D) is
activated by the vacuum tube.
3. Remove blower pipe assembly from unit.
A
B
C
D

Other manuals for Echo ES-210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Echo ES-210 and is the answer not in the manual?

Echo ES-210 Specifications

General IconGeneral
BrandEcho
ModelES-210
CategoryBlower
LanguageEnglish