19
STORAGE
LONG TERM STORAGE
(Over 60 Days)
Do not store your unit for a prolonged period of time
(60 days or longer) without performing protective
storage maintenance which includes the following :
1. Store unit in a dry, dust free place, out of the
reach of children.
WARNING DANGER
DO NOT STORE IN ENCLOSURE WHERE
FUEL FUMES MAY ACCUMULATE OR
REACH AN OPEN FLAME OR SPARK.
2. Drain or take out remaining chemical from the
tank.
Clean inside of chemical tank and spraying
hose.
3. Remove accumulation of grease, oil, dirt and
debris from exterior of unit.
4. Perform all periodic lubrication and services
that are required.
5. Inspect and adjust every part of the sprayer.
A. Completely clean every part, and repair, if
necessary.
B. Apply thin coating of oil on meral parts to
prevent rust.
C. Remove spraying hose and pipe.
6. Drain the fuel tank completely and pull the
starter handle several times to remove fuel
from the carburettor.
7. Remove the spark plug and pour 1/2
tablespoon of fresh, clean, two-sroke engine
oil into the cylinder through the spark plug
hole.
A. Place a clean cloth over the spark plug
hole.
B. Pull the recoil starter handle 2 or 3 times to
distribute the oil inside the engine.
C. Observe the piston location through the
spark plug hole. Pull the recoil handle
slowly until the piston reaches the top of its
travel and leave it here.
8. Install the spark plug (do not connect ignition
cable).
NOTE
For future reference, you should keep this
operator’s manual.