18
Input voltage frequency is too
high
Turn off all the power supplies (including the battery pack), let the unit stand for 5
minutes, then try to restart the unit by only charging with the AC charging cable;
Check if rmware updates are available, and upgrade to the latest version.
19
Input voltage frequency is too
low
30 Short circuit
Turn off all the power supplies (including the battery pack), let the unit stand for 5
minutes, and then try to restart the unit;
Check if rmware updates are available, and upgrade to the latest version.
31 Compressor start-up error
32 Compressor operation error
33 High appliance temperature
Turn off all the power supplies (including the battery pack), let the unit stand in a cool
place for 5 minutes, and then try to restart the unit;
Check if rmware updates are available, and upgrade to the latest version.
34 Low appliance temperature
Turn off all the power supplies (including the battery pack), let the unit stand at room
temperature for 5 minutes, and then try to restart the unit;
Check if rmware updates are available, and upgrade to the latest version.
35 Overvoltage
Turn off all the power supplies (including the battery pack), check if the air outlets are
obstructed and remove the obstructions, let the unit stand for 5 minutes, and then try
to restart the unit;
36 Undervoltage
37 Exhaust
38 Front fan error
Turn off all the power supplies (including the battery pack), and try to restart the unit;
Check if rmware updates are available, and upgrade to the latest version.
39 Rear fan error
40 Fluorine shortage
Turn off all the power supplies (including the battery pack), let the unit stand in a cool
place for 5 minutes, and then try to restart the unit;
41 Overload
Check if the front and rear air outlets are obstructed and remove any obstructions;
Check if rmware updates are available, and upgrade to the latest version.
50
Motor board communications
error
Turn off all the power supplies (including the battery pack), and try to restart the unit;
Check if rmware updates are available, and upgrade to the latest version.
51
Power board communications
error
52 WiFi communications error
53 Temperature sensor error
If the problem persists, please contact Ecoow after-sales service.

Other manuals for EcoFlow Wave 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EcoFlow Wave 2 and is the answer not in the manual?

EcoFlow Wave 2 Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
Wi-FiYes
Noise level56 dB
Refrigerating mediumR290
Cooling capacity (max)5100 BTU/h
Heating capacity (max)6100 BTU/h
Air conditioner functionsCooling, Heating
Operating temperature (T-T)5 - 50 °C
Refrigerating medium weight130 g
Suitable for room area up to10 m²
Cooling capacity in watts (max)1500 W
Heating capacity in watts (max)1800 W
International Protection (IP) codeIPX4
Cooling capacity in watts (nominal)- W
Heating energy efficiency (COP, W/W)-
Connected load820 W
AC input voltage100 - 240 V
AC input frequency50/60 Hz
Power consumption (cooling)550 W
Power consumption (heating)600 W
Hourly energy consumption (cooling)- kWh
Product colorBlack, Grey
Weight and Dimensions IconWeight and Dimensions
Depth297 mm
Width518 mm
Height336 mm
Weight14500 g