Unplug the product when it is not in use.
Before the unit is moved, make sure it is switched off and
unplugged.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied personel in
order to avoid a hazard.
The appliance shall be installed in accordance with national wiring
regulations. The unit is designed A-weighted sound pressure level
below 70 dB(A).
WARNING ON REFRIGERANT R290
This unit is designed only for use with R290 (propane) gas as the
designated refrigerant.
THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN
SHOULD ATTEMPT TO SERVICE!
The lack of smell does not indicate a lack of escaped gas.
No open ames, cigarettes or other possible sources of ignition should
be used in the vicinity of the unit.
Component parts are designed for propane and are non-incentive and
non-sparking. Component parts shall only be replaced with identical
repair parts.
THE UNIT MAY ONLY BE INSTALLED IN A ROOM WITH A MINIMUM
FLOOR AREA OF 4 m².
R290 is a ammable gas that is heavier than air. On this basis, if the gas
leaks from the unit, the concentration will be the highest at ground level.
However, the gas can be lifted (e.g. by draft, fan, etc.) to higher levels.
The R290 (propane) used in this unit has no odor.