EasyManuals Logo
Home>Ecolab>Control Systems>Apex2

Ecolab Apex2 User Manual

Ecolab Apex2
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Apex2 I/O Board Connections
Note: The components inside the Apex2 I/O enclosure are prewired
Pass wires through the hole in the Apex2 I/O enclosure for the cable sealing
block and connect to I/O Apex2 I/O board. Wires to pass through sealing block
include:
Controller via RS-485 Communication Cable
Inductive Probe
Solid Rinse Aid Dispenser Power
Rinse Aid IR Sensor, Out-of-product signal (connect to location ‘S’ on
Rinse Sensor Connector)
Liquid out-of-product sensor (if using liquid rinse aid or liquid sanitizer)
Blue to (-), Black to (S), Brown to (+)
Rinse Thermistor
Detergent Dispenser Lid Switch
Pressure Switch (optional)
12
1
8
APEX
DETERGENT
LID SWITCH
SANITIZER
MOTOR
PRESSURE
SWITCH
(OPTIONAL)
DETERGENT
VALVE
APEX RINSE
MAIN POWER
RED +
BLK -
BLK S
BRN +
BLK
RED
RED
BLK
BLK
-
RED
+
BRN
+
1
4
1
6
-
+
+
+
-
-
}
}
}
DETERGENT SIGNAL
RINSE SIGNAL
(NOT USED WITH
PRESSURE SWITCH)
SANITIZER SIGNAL
POWER IN
(FROM POWER SUPPLY)
(RETRO-FIT)
POWER IN
MACHINE SIGNALS
24 VDC
WHT
WHT
BLK
-
RINSE
THERMISTOR
BLK
-
CONTROLLER
LIQUID SANITIZER
SENSOR
GRY S
IR SENSOR
RINSE LID SWITCH
JUMPER
SANITIZER LID SWITCH
JUMPER
TERMINATING
PLUG
RINSE
MOTOR
CONDUCTIVITY
PROBE
LIQUID RINSE
SENSOR
BLU -
RED
+
24-240 VAC OR 24 VDC
Controller and terminating
plug connections can be
reversed without issue
12 / 5 VDC
I/O Board
Communication
(blinking)
Figure 4.11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Apex2 and is the answer not in the manual?

Ecolab Apex2 Specifications

General IconGeneral
BrandEcolab
ModelApex2
CategoryControl Systems
LanguageEnglish