3
Model
EcoloxTech 240
Power
AC 110/220V 50/60HZ 180W
Dimensions
32 x 17 x 42 cm (12.5 x 6.5 x 16.5 in)
Weight
11.8 kg (26 lbs.)
Production Cell Type
Single cell electrolysis for generating hypochlorous acid (HOCl)
Concentration Range
20 to 200 ppm of free available chlorine (FAC)
Ampere Settings
13 to 22 amp
Pump Speed Settings
0 to 19 (max. speed to min. speed)
Ambient Temperature
5 to 50 °C (41 to 122 °F)
Feed Water & Brine Temperature
10 to 30 °C (50 to 86 °F)
Inflow Water & Brine
Water Quality
Hardness less than 80 ppm required. Hardness over
80
ppm will damage electrolysis cells.
Humidity
Less than 96% Relative Humidity (RH)
Minimum Flow Rate
1 L/min
Maximum Water Pressure
40 PSI
Specifications
Requirements