8
SECURITY SEQUENCE:
UNLOCKS KEYPAD AT ANY TIME
TO ENTER INFORMATION
1) Your new unit will prompt you to enter the security
sequence (up, down, up).
2) Each time you want to enter information into the operat-
ing unit, you first need to touch the keypad and then
enter the security sequence.
INCREASES or DECREASES values
when depressed.
Holding down keys will run
the numbers faster.
RIGHT Arrow when correct values are
entered. Both will move cursor to the
various number fields within the LCD,
and RIGHT will return back to first
cursor position, when at the end of a line.
Either button will allow you to change
TIME, DATE, or DAY of the week.
A “Super Cap” instead of a battery will
give you an operating clock of at least 100 hours if
power is interrupted.
CLOCK
DATE
SECURITY SEQUENCE
9
Tells ECOsmarte unit maximum hours your POOL is
running. The ECOsmarte unit will not output outside of the
programmed pool run time. NOTE: Pool Heater must
turnoff 15 minutes before the pool to avoid plumbing
damage due to heat.
To setup the number of hours of OXYGEN your pool
needs per day. (i.e. OXYGEN purifies water in plumbing
6-10 hours per day.)
COPPER IONization is delivered to the pool for the
number of hours programmed. Press ION to change the
Start and Stop times. Press OXY to stop ionizing
immediately when Copper ppm is reached. At setup
confirm all settings after using this button.
This key will change default from POOL = OXY to
POOL = ION Ideal at new fill or when you wish to
IONIZE today. Will auto repeat, so you must press
OXY when ION levels are reach.
Allows you to select future day for Copper to IONIZE
your Pool or to oxidize and ionize on the same day. Will
repeat each week if function is not turned OFF. THIS
key also allows completion of ALL programming
tasks.
Activates Pool pump Relay option, CO2, PH sensor, a
visual or audio alarm for PH range and power to cham-
bers and CU sensors ( if technology becomes available),
TDS and Water Temp are Future upgrades, as is remote
computer windows interface.
POOL
OXY
ION
CU
MAN
NEXT
ENTER
ACC
Your unit retains all values in the RAM
programmed for seven days consecu-
tive without power to ECOsmarte box.
No battery is utilized.
PROGRAMMING MEMORY