INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS ECOSOFT ROBUST MINI,
ROBUST 1500, ROBUST PRO, ROBUST 3000, ROBUST 3000MAX, ROBUST 4000
ENG
1 Remove the reverse osmosis system from and the box check that all parts are inside the bag.
2 Shut o water supply in place of installaon and open a water tap for 1 minute to relieve
pressure in the system. Then close the tap.
3 Drain saddle ts most standard drain pipe. Install
the drain saddle on drain pipe as follows. Bore 5
mm hole in the drain pipe, apply rubber gasket with
scky base (included in the package). Install drain
saddle on top of the gasket so that push-t ng
in the saddle is located precisely above the hole in
drain pipe. Tighten nuts on drain saddle fasteners
with a wrench. Insert black tube in the push-t ng
in drain saddle. Connect the other end of black tube
with drain port of the RO system’s push-t port rack.
 Put a few turns of PTFE tape on tank nipple thread.
Screw tank valve on the tank nipple. Turn the valve
fully o.




5 Install the faucet.
 To install puried water faucet bore a 12,5 mm
diameter hole in desired locaon on sink or
countertop.
CAUTION!      
      


 Mount the faucet over the hole on top of small
rubber washer, chrome plated base, and large
rubber washer. Fix the faucet rmly with plasc
washer, lock washer, and nut put on the faucet
shank underneath sink surface.
 Put compression nut on free end of blue tube, then
put on ferrule and put insert inside the tube.
 Push the end of blue tube inside the shank boom,
seat the ferrule against shank boom and screw
compression nut snugly on shank thread. The faucet
should now be rmly xed on top of sink, and blue
tube ghtly seated in compression ng at the
boom of faucet shank.
6 Install replacement lters to the 1st and 2nd housings (le to right).
7 Install the housings back on the system. Hand ghten only.
PTFE seal
tank
tank valve
small rubber gasket
chrome-plated cover
large rubber gasket
large plasc gasket
lock washer
nut
counter
1/4 ferrule
1/4 compression nut
blue tube
plasc insert

Table of Contents

Other manuals for Ecosoft ROBUST 3000