Manual for Ecosoft Pink
softeners

Questions and Answers

  • C
    Christine FuentesAug 13, 2025
    Why is the service flow capacity decreased in my Ecosoft Water Dispenser?
    • J
      jameswhiteAug 13, 2025
      If the Ecosoft Water Dispenser experiences decreased service flow capacity, it could be due to several reasons: * **Decreased supply water pressure:** Increase the supply water pressure. * **Clogged filter bed:** See paragraph 3. * **Obstructed/clogged drain line:** Clean the drain line. * **Clogged control valve:** Inspect and clean the control valve. * **NHWBP/MAV failure (if used):** Inspect and repair the motorized valve.
  • M
    Miguel DavisAug 17, 2025
    What to do if brine will not draw during regeneration in Ecosoft FU1013CABDVUP?
    • A
      Angela RichAug 17, 2025
      If the brine will not draw during regeneration or not all brine will draw in your Ecosoft Water Dispenser, consider the following: 1. **Low supply water pressure:** Check the supply water pressure. 2. **Clogged injector or brine tube:** Clean the brine injector and/or brine tube. 3. **Clogged basket or salt crystals on ball in air check valve:** Clean the air check valve basket and/or ball. 4. **High pressure drop on the filter:** See paragraphs 1 and 4. 5. **Air is injected:** Check airtightness of the drain line. 6. **Control valve settings changed:** Increase brine stage duration.
  • H
    Hector ArcherAug 20, 2025
    Why Ecosoft Water Dispenser water quality decreased?
    • K
      Kenneth MartinezAug 20, 2025
      The decreased quality of treated water in your Ecosoft Water Dispenser could be caused by: * **Faulty chemical analysis of water:** Perform one more test using freshly prepared reagents. * **Supply water chemistry has changed:** Make new check analysis and if changed contact your dealer. * **Bypass valve is set to bypass:** Turn bypass valve to operating position. * **Riser pipe or seals are damaged:** Take apart the filter, inspect and replace or lubricate pipe and seals if necessary. * **Clogged filter bed:** See paragraph 3. * **Filter media loss:** See paragraph 4. * **Improper filter regeneration:** See paragraph 6. * **Leakage of raw water inside the control valve:** Take apart the control valve, inspect and replace or lubricate the seals if needed.
  • H
    huangdavidAug 25, 2025
    What to do if the brine tank is not refilled in Ecosoft FU1013CABDVUP?
    • J
      James PageAug 25, 2025
      The brine tank in your Ecosoft Water Dispenser might not be refilling or is refilling with less water than needed due to: * **Low supply water pressure:** Check supply water pressure. * **Clogged injector or brine tube:** Clean brine injector and/or brine tube. * **Stuck ball in the air check valve:** Clean the air check valve. * **Control valve settings changed:** Check the duration of brine tank refill and correct if necessary.
  • C
    Colin MezaAug 28, 2025
    Why is the brine tank refilling with excess water in my Ecosoft FU1013CABDVUP Water Dispenser?
    • M
      Michael MoranAug 28, 2025
      If the brine tank in your Ecosoft Water Dispenser is refilling with excess water, it could be due to: * **High main water pressure:** Check water pressure. Install pressure regulator if needed. * **Control valve settings changed:** Check the duration of brine tank refill and correct if necessary.
  • C
    crystalmoralesAug 31, 2025
    How to fix a clogged filter bed in Ecosoft FU1013CABDVUP?
    • R
      Robert RiveraAug 31, 2025
      A clogged filter bed in your Ecosoft Water Dispenser can be caused by: * **Insufficient backwash flow rate:** Check backwash flow rate. If supply pressure is within the limits and the flow rate is insufficient, inspect and clean the drain line flow control or replace it if needed. * **Insufficient backwash stage:** Increase the duration of backwash stage. * **Clogged top distributor:** Clean the top distributor. * **Excessive backwash flow rate:** Measure backwash flow rate. If supply pressure is normal and the flow rate is exceeding, consider changing the drain line flow control.
  • T
    Tracie JohnsonSep 5, 2025
    What causes filter media entrainment in Ecosoft FU1013CABDVUP Water Dispenser?
    • J
      juanbestSep 5, 2025
      Filter media entrainment in your Ecosoft Water Dispenser can occur for several reasons: * **Filter media is entrained and discharged during backwash:** Replace the top distributor if needed. * **Filter media is entrained and discharged during service:** Replace the bottom distributor if needed. * **No electric power:** Check power supply. * **No/insufficient salt in brine tank:** Check the amount of salt in brine tank and add salt if needed. * **Brine is not sucked in during regen., or not all brine is drawn:** See paragraph 6. * **Control valve is out of order or settings were changed:** Check the control valve and its settings (see the manual for the control valve).
  • N
    nreevesSep 8, 2025
    Why is there excess salt use per regeneration in my Ecosoft FU1013CABDVUP?
    • G
      gkingSep 8, 2025
      Excess use of salt per regeneration in your Ecosoft Water Dispenser may be due to: * **Control valve settings changed:** Decrease the amount of salt per regeneration in the control valve settings. * **Brine tank filled with excess water:** See paragraph 9.