6 7
MANUAL FOR ECOSOFT COMPACT WATER SOFTENERS
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibit
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2023 ecosoft.com
2. TECHNICAL DATA
2.2 Pink series
TECHNICAL SPECIFICATION:
Parameter
FU1013CABDVUP FU1016CABDVUP FU1024CABDVUP
Operating flow rate, m
3
/h
1.2
1.5
1.8
Quantity of media, L
10 15 2
0
2
3
5
Usage of salt per regeneration
1
, kg 1.0
1.5 2.0
Usage of water per regeneration
(= discharge per regeneration), m
3
0.08 0.1 0.12
Duration of regeneration, minutes 80–110
Pressure drop in service mode, bar 0.5
Inlet pressure, bar 2–6
Electrical requirements 230 V, 50 Hz
Power consumption, W 30
Inlet/outlet pipe connections
3/4’’
Dry weight, kg
18.8 22.2 32.5
Overall dimensions,
(Width × Depth × Height), cm
270 х 430 х 469 270 х 430 х 539 270 х 430 х 741
Volume capacity, m
3
@250 mg/L CaCO
3
influent harness
INFLUENT WATER LIMITATIONS:
Hardness 750 mg/L CaCO
3
Iron 0.2 mg/L
Manganese 0.05 mg/L
Chemical Oxygen Demand 5 mg/L O
2
Sediment prelter rating 100 μm
Temperature of water
2
+4…+30 °C