2. TECHNICAL DATA
2.2 Pink series
TECHNICAL SPECIFICATION:
Parameter
FU1013CABDVUP FU1016CABDVUP FU1024CABDVUP
Operating flow rate, m
3
/h
1.2
1.5
1.8
Quantity of media, L
10 15 2
0
2
3
5
Usage of salt per regeneration
1
, kg 1.0
1.5 2.0
Usage of water per regeneration
(= discharge per regeneration), m
3
0.08 0.1 0.12
Duration of regeneration, minutes 80–110
Pressure drop in service mode, bar 0.5
Inlet pressure, bar 2–6
Electrical requirements 230 V, 50 Hz
Power consumption, W 30
Inlet/outlet pipe connections
3/4’’
Dry weight, kg
18.8 22.2 32.5
Overall dimensions,
(Width × Depth × Height), cm
270 х 430 х 469 270 х 430 х 539 270 х 430 х 741
Volume capacity, m
3
@250 mg/L CaCO
3
influent harness
INFLUENT WATER LIMITATIONS:
Hardness 750 mg/L CaCO
3
Iron 0.2 mg/L
Manganese 0.05 mg/L
Chemical Oxygen Demand 5 mg/L O
2
Sediment prelter rating 100 μm
Temperature of water
2
+4…+30 °C