64
NOTE: Before beginning the filter replacement process, ensure all internal components are cool to the
touch. Components can be very hot after long run cycles and can present risk of injury.
Replacement Guide:
1. Turn off power to nitrogen generator.
2. Verify that all pressure has been drained from inlet line by examining pressure gauge on excess
air bleed-off regulator.
3. Remove filter housing of 5-Micron Coalescing Filter Housing by pulling down on the blue housing
lock and turning filter housing counter-clockwise.