TROUBLESHOOTING
Troubles Possible Causes Suggested Remedies
The unit
does not
start
when
pressing
power
button.
• Water full indicator
lamp blinks and water
tank is full.
• Room temperature is
higher than the setting
temperature.(Electric
heating mode)
• Room temperature is
lower that the setting
temperature.(Cooling
mode)
• Drain the water out of the
water tank.
• Adjust the temperature.
The unit
doesn’t
cool
enough.
• The doors or windows
are not closed.
• There are heat
sources inside the
room.
• Hot air exhaust hose
is not connected or
blocked.
• Temperature setting is
too high.
• Air inlet in blocked.
• Make sure all the
windows and doors are
closed.
• Remove the heat sources
if possible.
• Connect or clean the hot
air exhaust hose.
• Reset the temperature.
• Clean the air inlet.
Auto
Power-Off
in heating
mode.
• Heating protection,
when the temperature
at the air outlet
exceeds 70 degrees,
the unit will power off
automatically.
• Allow room temperature
to cool before re-starting
the unit.
Noisy. • The ground is not
level or not flat
enough.
• The sound comes
from the flowing of the
refrigerant inside the
air conditioner.
• Place unit on a flat, level
ground if possible.
E0 Code. • Room temperature
sensor failed.
• Replace room
temperature sensor.
E2 Code. • Water tank full • Please empty the water
tank.
TABLE ERP ED-7016
Information requirements for single
and double duct air conditioners
P
Information to identify the model(s) to
which the information relates to:
Description Symbol Value Unit
Rated capacity for cooling Prated 2,05 kW
Rated capacity for heating Prated N/A kW