TROUBLESHOOTING
Troubles Possible Causes Suggested Remedies
The unit
does not
start
when
pressing
power
button.
Water full indicator
lamp blinks and water
tank is full.
Room temperature is
higher than the setting
temperature.(Electric
heating mode)
Room temperature is
lower that the setting
temperature.(Cooling
mode)
Drain the water out of the
water tank.
Adjust the temperature.
The unit
doesn’t
cool
enough.
The doors or windows
are not closed.
There are heat
sources inside the
room.
Hot air exhaust hose
is not connected or
blocked.
Temperature setting is
too high.
Air inlet in blocked.
Make sure all the
windows and doors are
closed.
Remove the heat sources
if possible.
Connect or clean the hot
air exhaust hose.
Reset the temperature.
Clean the air inlet.
Auto
Power-Off
in heating
mode.
Heating protection,
when the temperature
at the air outlet
exceeds 70 degrees,
the unit will power off
automatically.
Allow room temperature
to cool before re-starting
the unit.
Noisy. The ground is not
level or not flat
enough.
The sound comes
from the flowing of the
refrigerant inside the
air conditioner.
Place unit on a flat, level
ground if possible.
E0 Code. Room temperature
sensor failed.
Replace room
temperature sensor.
E2 Code. Water tank full Please empty the water
tank.
TABLE ERP ED-7016
Information requirements for single
and double duct air conditioners
P
Information to identify the model(s) to
which the information relates to:
Description Symbol Value Unit
Rated capacity for cooling Prated 2,05 kW
Rated capacity for heating Prated N/A kW