Installation manual: Preparation
1. Installing the appliance
1.1 Technical information
Please refer to the technical information at the end of the manual (pages I to IV) for information relating to:
• Package contents
• Technical speci cations.
1.2 Speci c instructions for installation in a bathroom
• Installation outside areas 1 and 2 (NF C 15-100).
If the bathroom dimensions do not allow the water heater to be positioned outside volumes 1 and 2:
M
M
M
Volume
1
Volume
2
M
M
M
Volume
1
Volume
2
M
M
M
Volume
1
Volume
2
It is then possible in area V2
or possible in area V1, if:
- the water heater is horizontal and positioned as
high up as possible (40, 65 and 80 L only)
- the pipes are made from a conductive material
- the water heater is protected by a circuit breaker
with a residual differential current (30 mA)
connected upstream of the water heater