EasyManua.ls Logo

EdgeStar AP10002BL - 1 Specifications

EdgeStar AP10002BL
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
1 Specifications
Parameter
Unit
Value
Model
AP10002BL
Power
Supply
Rated Voltage
V~
115
Rated Frequency
Hz
60
Phases
1
Cooling Capacity
Btu/h
10000
Heating Capacity
Btu/h
/
Cooling Power Input
W
1120
Heating Power Input
W
/
Cooling Power Current
A
9
Heating Power Current
A
/
Rated Input
W
1280
Rated Current
A
12.6
Input of Heater
W
/
Air Flow Volume(H/M/L)
CFM
230/200/180
Dehumidifying Volume
Pint/h
2.54
EER
(Btu/h)/W
8.9
COP
(Btu/h)/W
/
SEER
W/W
/
HSPF
W/W
/
Application Area
yd2
16 37/50-24
Climate Type
T1
Isolation
I
Moisture Protection
IPX0
Design Pressure Hi. Side
P.S.i
550
Design Pressure Low Side
P.S.i
240
Throttling Method
Capillary
Defrosting Method
/
Fuse
A
3.15
Operation Temp
ºF
61~86
Ambient Temp (Cooling)
ºF
64~95
Ambient Temp (Heating)
ºF
/
Sound Pressure Level (H/M/L)
dB (A)
53/51/49
Sound Power Level (H/M/L)
dB (A)
63/61/59
Dimension (WXHXD)
inch
13 2/5X30 5/7X15 1/2
Dimension of Carton Box (L/W/H)
inch
15 5/8X21 1/2X31 1/2
Dimension of Package (L/W/H)
inch
15 3/4X21 2/3X32
Net Weight
oz
882
Gross Weight
oz
1094
Refrigerant
R410A
Refrigerant Charge
oz
18.3

Other manuals for EdgeStar AP10002BL

Related product manuals