5 Modes and Operating Conditions
5.1 Terms and Definitions
TA: Ambient indoor temperature.
TS: Set temperature.
5.2 Cooling Mode (Blue Light)
The cooling temperature can be set from 64 to 90.
The timer function works in cooling mode.
The compressor will run when the difference between the set temperature and the actual ambient room
temperature conforms to the chart below:
When TA≤TS (for 1 minute) the compressor turns off.
When TA>TS+2 the compressor turns on.
5.3 Fan Only Mode (Green Light)
If the temperature can’t be controlled by the selected mode and the room ambient temperature is shown
on the display the unit will default to fan only mode.
The readout can only display a temperature of 32 to 99 (0 to 37.) lf the temperature is out of that
range the display will show LO or HI.
The Timer function works in fan only mode.
(TA-Ts)
+2
0
Operation conditon
compressor off with a delay of 1 minute
compressor on