4. TROUBLESHOOTING
4-3 SERVICE
DIAGNOSIS CHART
Prob
lem
Poss
ible
Caus
e
App
liance does not operate.
Not p
lugged in.
The appliance is turned off.
The circuit breaker tripped or a blown fuse.
Appl
iance is not cold enough.
Chec
k the temperature control setting. External
environment may require a higher
setting.
The door is opened too often.
The door is not closed completely.
The door gasket does not seal properly.
Turns on and off f
requently.
The room tem
perature is hotter than normal.
A large amount of contents has been added to the wine chiller.
The door is opened too often.
The door is not closed completely.
The temperature control is not set correctly. The door
gasket does not seal properly.
The li
ght does not work.
Not p
lugged in.
The circuit breaker tripped or a blown fuse. The bulb has
burned out.
The light button is “OFF”.
Energy conservation button is on.
Vibrations
.
Chec
k to assure that the Wine Chiller is level.
The Wine Chiller seems to make too much noise.
The rattl
ing noise may come from the flow of the refrigerant,
which is normal.
As each cycle ends, you may hear gurgling
sounds caused by the flow of refrigerant in your
Wine Chiller.
Contraction and expansion of the inside walls may cause
popping and crackling noises.
The Wine Chiller is not level.
The door wil
l not close properly.
The Wine Chiller is
not level.
The door was reversed and not properly installed. The gasket is
dirty.
The shelves are out of position.
Display error code “E1”
The air sensor is open circuit failed. Connection main control
PCB is with white color wires. Check the circuit, if it is normal,
the sensor need to be replaced.
Dis
play error code “E2”
The air sensor is short circuit failed. Connection main control
PCB is with white color wires. Check the circuit, if it is normal,
the sensor need to be replaced.
Dis
play error code “E3”.
The defrost sensor is open circuit failed. Connection main
control PCB is with red color wires. Check the circuit, if it is
normal, the sensor need to be replaced.
Dis
play error code “E4”.
The defrost sensor is short circuit failed. Connection main
control PCB is with red color wires. Check the circuit, if it is
normal, the sensor need to be replaced.